A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Anteroposterior and rotational stability in fixed and mobile bearing unicondylar knee arthroplasty: a cadaveric study using the robotic force sensor system. | LitMetric

Purpose: Different bearing designs in unicondylar knee arthroplasty (UKA) have been developed in order to influence the rate of polyethylene wear. Increased anteroposterior translation and rotation after UKA has been hypothesized due to changes in joint surface geometry. The mobile bearing design was expected to show increased anteroposterior translation compared to the fixed bearing and biconcave bearing design.

Methods: Six human cadaver knees were used for the tests. Anteroposterior and rotational knee stability was analysed in 0°, 30°, 60°, 90° and 120° of knee flexion using a robotic testing system (KR 125, KUKA Robots Augsburg, Germany). Three forces and moments were measured in a Cartesian coordinate system with a resolution of 1.0 N and 0.1 Nm.

Results: There was no difference between the native knees and the knees after UKA in AP translation and rotation in all knee flexion angles. The factor knee flexion angle had a significant impact on the anterior translation when the type of bearing was neglected (p ≤ 0.015).

Conclusion: This study shows that the natural knee stability in AP translation and rotation can be preserved in UKA. The preserved knee stability in different planes after UKA underlines the advantage of UKA when surgery is required in osteoarthritic changes of the medial compartment.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00167-012-2157-5DOI Listing

Publication Analysis

Top Keywords

translation rotation
12
knee stability
12
knee flexion
12
anteroposterior rotational
8
mobile bearing
8
knee
8
unicondylar knee
8
knee arthroplasty
8
increased anteroposterior
8
anteroposterior translation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!