Objectives: Postoperative pain after laparoscopic surgery is less intense than after laparotomy and patients may benefit from an intraperitoneal injection of local anesthetic and opioids. We aimed to compare intraperitoneal 0.75% ropivacaine with 0.75% ropivacaine plus meperidine for postoperative analgesia in patients undergoing gynecologic laparoscopy.
Methods: At the end of gynecologic laparoscopy, in a double-blind, randomized manner, one of the following injections was given intraperitoneally. Patients were allocated into three groups: Patients in R Group (n=18) were given 0.75% ropivacaine 3 mg/kg in 200 mL saline; patients in RM Group (n=17) were given meperidine 50 mg plus 0.75% ropivacaine 3 mg/kg in 200 mL saline; patients in C Group (n=18) were given 200 mL saline through the trocars. All patients were given diclofenac sodium when they had pain (VAS 3) and 1 mg/kg meperidine i.v. was also given when pain persisted.
Results: The pain scores and analgesic requirements during the first postoperative hour were significantly lower in the RM Group than those in the R and C Groups. Beyond that time, the pain scores were similar in all groups and there were no differences in total analgesic requirement in 24 h between groups. The three groups were comparable for shoulder pain and side effects.
Conclusion: The intraperitoneal infiltration of 0.75% ropivacaine plus meperidine reduced pain scores and analgesic requirement during the first one hour after gynecologic laparoscopy compared with the intraperitoneal infiltration of ropivacaine or saline.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5505/agri.2012.21033 | DOI Listing |
Eur J Clin Pharmacol
January 2025
Department of Anesthesiology, the Second Afffliated Hospital of Soochow University, Suzhou City, People's Republic of China.
Objective: In part I, measure the EC50 of sufentanil in obese and non-obese parturients combined with 0.1% ropivacaine and compare the differences. Similarly, in part II, measure the EC50 of ropivacaine in obese and non-obese parturients combined with 0.
View Article and Find Full Text PDFMedicine (Baltimore)
September 2024
Department of Anesthesia, The First People's Hospital of Pinghu, Zhejiang, China.
Background: Studies have shown that the ideal dose of epidural dexmedetomidine is 0.4 μg mL-1 for epidural labor analgesia. However, the appropriate dose of ropivacaine when combined with 0.
View Article and Find Full Text PDFHeliyon
May 2024
Department of Anesthesiology, Affiliated Xiaoshan Hospital, Hangzhou Normal University, Hangzhou, China.
Background: Epidural nonopioid adjuvants also reduce local anesthetic use. We aimed to test the hypothesis that, compared with the present standard fentanyl, the hourly consumption of local anesthetic was at least as good when dexmedetomidine or esketamine was combined with local anesthetic for patient-controlled epidural analgesia (PCEA).
Methods: A total of 120 laboring nulliparous subjects requiring labor analgesia were recruited for the final statistical analysis.
J Anaesthesiol Clin Pharmacol
July 2023
Department of Pediatric Surgery, All India Institute of Medical Sciences, New Delhi, India.
Background And Aims: Comparison of analgesic efficacy of ultrasound-guided transmuscular quadratus lumborum block (QL-3) and erector spinae block (ESP) in children undergoing open pyeloplasty was done in this study.
Material And Methods: This was a randomized, double-blinded, controlled study conducted in a tertiary care center, operating rooms, post-anesthesia care unit (PACU), and paediatric surgical ward. Sixty children of age 1-6 years, with American Society of Anesthesiologists (ASA) status I or II, undergoing elective open pyeloplasty were included in the study.
J Anesth
June 2024
Department of Anesthesiology, General Hospital of Northern Theater Command of the Chinese People's Liberation Army, Shenyang, China.
Purpose: More literature studies have reported that alfentanil is safe and effective for labor analgesia. However, there is no unified consensus on the optimal dosage of alfentanil used for epidural analgesia. This study explored the concentration at 90% of minimum effective concentration (EC90) of alfentanil combined with 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!