Objective: To assess the feasibility of single-breath-hold three-dimensional cine b-SSFP (balanced steady-state free precession gradient echo) sequence (3D-cine), accelerated with k-t BLAST (broad-use linear acquisition speed-up technique), compared with multiple-breath-hold 2D cine b-SSFP (2D-cine) sequence for assessment of left ventricular (LV) function.

Methods: Imaging was performed using 1.5-T MRI (Achieva, Philips, The Netherlands) in 46 patients with different cardiac diseases. Global functional parameters, LV mass, imaging time and reporting time were evaluated and compared in each patient.

Results: Functional parameters and mass were significantly different in the two sequences [3D end-diastolic volume (EDV) = 129 ± 44 ml vs 2D EDV = 134 ± 49 ml; 3D end-systolic volume (ESV) = 77 ± 44 ml vs 2D ESV = 73 ± 50 ml; 3D ejection fraction (EF) = 43 ± 15% vs 2D EF = 48 ± 15%; p < 0.05], although an excellent correlation was found for LV EF (r = 0.99). Bland-Altman analysis showed small confidence intervals with no interactions on volumes (EF limits of agreement = 2.7; 7.6; mean bias 5%). Imaging time was significantly lower for 3D-cine sequence (18 ± 1 s vs 95 ± 23 s; p < 0.05), although reporting time was significantly longer for the 3D-cine sequence (29 ± 7 min vs 8 ± 3 min; p < 0.05).

Conclusions: A 3D-cine sequence can be advocated as an alternative to 2D-cine sequence for LV EF assessment in patients for whom shorter imaging time is desirable.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3288975PMC
http://dx.doi.org/10.1007/s13244-010-0056-1DOI Listing

Publication Analysis

Top Keywords

cine b-ssfp
16
assessment left
8
left ventricular
8
k-t blast
8
multiple-breath-hold cine
8
functional parameters
8
parameters mass
8
magnetic resonance
4
resonance assessment
4
ventricular volumes
4

Similar Publications

Article Synopsis
  • The study introduces IMplicit UNrolled NEtworks (IMUNNE) as a new training strategy for dynamic MRI reconstruction, addressing issues of long training times and high GPU memory usage.
  • IMUNNE frames the MRI reconstruction as an implicit fixed-point equation and uses a gradient approximation method, allowing it to work efficiently with deep learning models.
  • Results show that IMUNNE improves image quality and significantly decreases training and inference times compared to existing methods, making it a promising solution for efficient cine MRI imaging.
View Article and Find Full Text PDF

Background: To assess the accuracy and reproducibility of right ventricular (RV) and left ventricular (LV) function and flow measurements in children with repaired tetralogy of Fallot (rTOF) using four-dimensional (4D) flow, compared with conventional two-dimensional (2D) magnetic resonance imaging (MRI) sequences.

Methods: Thirty pediatric patients with rTOF were retrospectively enrolled to undergo 2D balanced steady-state free precession cine (2D b-SSFP cine), 2D phase contrast (PC), and 4D flow cardiac MRI. LV and RV volumes and flow in the ascending aorta (AAO) and main pulmonary artery (MPA) were quantified.

View Article and Find Full Text PDF

Objective: To investigate the feasibility of cine three-dimensional (3D) balanced steady-state free precession (b-SSFP) imaging combined with a non-local means (NLM) algorithm for image denoising in evaluating cardiac function in children with repaired tetralogy of Fallot (rTOF).

Materials And Methods: Thirty-five patients with rTOF (mean age, 12 years; range, 7-18 years) were enrolled to undergo cardiac cine image acquisition, including two-dimensional (2D) b-SSFP, 3D b-SSFP, and 3D b-SSFP combined with NLM. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) of the two ventricles were measured and indexed by body surface index.

View Article and Find Full Text PDF

We aimed to assess left atrial (LA) strain before LA dilatation in patients with repaired tetralogy of Fallot (rTOF) compared with healthy controls. We also determined the effects of right atrial (RA) dilatation on LA performance using cardiovascular magnetic resonance-feature tracking (CMR-FT). Forty-nine pediatric patients with rTOF and 36 age- and sex-matched healthy controls were prospectively recruited between June 2017 and August 2019.

View Article and Find Full Text PDF

The pathophysiology behind thrombus formation in paroxysmal atrial fibrillation (AF) patients is very complex. This can be due to left atrial (LA) flow changes, remodeling, or both. We investigated differences for cardiovascular magnetic resonance (CMR)-derived LA 4D flow and remodeling characteristics between paroxysmal AF patients and patients without cardiac disease.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!