Purpose: We aimed to assess the role of single photon emission computed tomography-computed tomography (SPECT-CT) for characterizing isolated vertebral lesions observed by bone scintigraphy compared to planar scintigraphy, SPECT, and CT, and to evaluate the impact of SPECT-CT on patient management.

Materials And Methods: Data from 99 patients (mean age, 52.4±18.9 years; females, 58.5%) with 108 isolated vertebral lesions visible on planar bone scintigraphy, who had undergone SPECT-CT of a selected volume, were retrospectively analyzed. Planar scintigraphy, SPECT, CT, and SPECT-CT images were independently evaluated in separate sessions to minimize recall bias. A scoring scale of 1 to 5 was used, with 1 being definitely metastatic, 2 most likely metastatic, 3 indeterminate, 4 most likely benign, and 5 definitely benign. Sensitivity, specificity, and predictive values were calculated; a score ≤3 was defined as metastatic. The areas under the receiver operating characteristic curve were calculated and compared. Clinical and imaging followup with or without histopathology were used as a reference standard.

Results: Among the 108 lesions, 49 were indeterminate on planar scintigraphy, 16 on SPECT, and one each on SPECT-CT and CT. SPECT-CT was superior to both planar scintigraphy (P < 0.001) and SPECT alone (P = 0.014), but not to CT (P = 0.302). CT was superior to planar scintigraphy (P < 0.001) but only slightly superior to SPECT (P = 0.063). SPECT-CT correctly characterized 96% of the indeterminate lesions observed by planar scintigraphy. SPECT-CT had an impact on the clinical management of 60.6% patients compared to planar scintigraphy and 18.1% compared to SPECT.

Conclusion: SPECT-CT is better than planar scintigraphy and SPECT alone, but not CT alone, for characterizing equivocal vertebral lesions that are observed by bone scintigraphy, thus SPECT-CT can have a significant impact on patient management.

Download full-text PDF

Source
http://dx.doi.org/10.4261/1305-3825.DIR.5790-12.1DOI Listing

Publication Analysis

Top Keywords

planar scintigraphy
36
scintigraphy spect
20
vertebral lesions
16
lesions observed
16
bone scintigraphy
16
scintigraphy
13
isolated vertebral
12
observed bone
12
planar
10
spect-ct
10

Similar Publications

Background: In radioembolization therapy for hepatic malignancies, the accurate estimation of lung shunt fraction (LSF) is crucial to minimize the risk of radiation-induced pneumonitis and fibrosis due to hepatopulmonary shunting of yttrium-90 (90Y)-microspheres. This study aimed to compare the accuracy and precision of LSF estimation using technetium-99m macroaggregated albumin single photon emission computed tomography ([99mTc]Tc-MAA SPECT) LSF, [99mTc]Tc-MAA planar LSF, and 90Y PET LSF in patients undergoing 90Y-radioembolization.

Material And Methods: A retrospective study was conducted involving 15 patients diagnosed with hepatocellular carcinoma (HCC) or liver metastases and planned to undergo transarterial radioembolization with 90Y SirSpheres after multidisplinary team discussion.

View Article and Find Full Text PDF

AI-Based Noise-Reduction Filter for Whole-Body Planar Bone Scintigraphy Reliably Improves Low-Count Images.

Diagnostics (Basel)

November 2024

Division of Nuclear Medicine and Translational Imaging, Department of Medical Imaging, Faculty of Medicine, University of Debrecen, H-4032 Debrecen, Hungary.

: Artificial intelligence (AI) is a promising tool for the enhancement of physician workflow and serves to further improve the efficiency of their diagnostic evaluations. This study aimed to assess the performance of an AI-based bone scan noise-reduction filter on noisy, low-count images in a routine clinical environment. : The performance of the AI bone-scan filter (BS-AI filter) in question was retrospectively evaluated on 47 different patients' Tc-MDP bone scintigraphy image pairs (anterior- and posterior-view images), which were obtained in such a manner as to represent the diverse characteristics of the general patient population.

View Article and Find Full Text PDF

We present a rare case of physiological uptake of [ Lu]Lu-DOTATATE in the gallbladder, observed post-therapy, in a 47-year-old man with grade I duodenal neuroendocrine tumor (NET), despite no uptake being observed pre-therapy in the somatostatin receptor-positron emission tomography. On planar scintigraphy, the gallbladder uptake could have been misidentified as liver metastasis. By utilizing single photon emission computed tomography/computed tomography imaging, we were able to precisely localize the tracer and obtain anatomical morphological characteristics, thereby averting the potential for misinterpretation of liver metastasis resulting from the gallbladder's physiological uptake of [ Lu]Lu-DOTATATE in NET patients.

View Article and Find Full Text PDF

: This study investigated the feasibility of using a quantitative diagnostic method based on Tc-pyrophosphate scintigraphy (PYP) lateral planar images to differentiate between PYP-positive (myocardial uptake) and false-positive (blood pool uptake) scans. : The study included 93 consecutive patients with suspected transthyretin amyloid cardiomyopathy (ATTR-CM) who underwent PYP between April 2022 and December 2023. Patients were categorized using planar anterior PYP images according to the Perugini visual grading system; patients with grades ≥ 2 were analyzed.

View Article and Find Full Text PDF

: Lateral planar Tc-pyrophosphate (PYP) imaging is recommended as a standardized acquisition method because it helps separate extracardiac uptake from the myocardium. We evaluated its discriminatory performance in detecting myocardial PYP uptake, using single-photon emission computed tomography (SPECT) as a reference standard. : We retrospectively evaluated 170 patients who underwent PYP imaging for suspected transthyretin cardiac amyloidosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!