Background: TKA with retention of the anterior cruciate ligament (ACL) may improve kinematics and function. However, conflicting reports exist concerning the prevalence of intact ACLs at the time of TKA.
Questions/purposes: Therefore, we asked: (1) what was the ACL status at TKA; (2) what was the sensitivity and specificity of the Lachman test; (3) did MRI ACL integrity correlate with intraoperative observation; (4) did MRI tibial wear patterns correlate with ACL integrity; and (5) did ACL status depend on age or sex?
Methods: We evaluated 200 patients for ACL integrity at the time of TKA. All patients underwent a Lachman test under anesthesia. Intraoperatively, the ACL was characterized as intact, frayed, disrupted, or absent. In 100 patients, MRIs were performed, from which the ACL was graded as intact, indeterminate, or disrupted, and the AP location of tibial wear was categorized.
Results: The ACL was intact in 155 patients (78%). The Lachman test alone had poor diagnostic ability. The MRI predicted a tear, but we observed two ACLs with indeterminate status that were disrupted. All knees with anterior wear on the medial tibial condyle had an intact ACL (n = 45), and all knees with posterior wear on the medial tibial condyle had a disrupted ACL (n = 8).
Conclusions: Although the Lachman test alone had poor sensitivity, when combined with MRI they together provide a sensitivity of 93.3% and specificity of 99%, which we believe makes these reasonable tests for assessing ACL status in the arthritic knee.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3528932 | PMC |
http://dx.doi.org/10.1007/s11999-012-2505-2 | DOI Listing |
Cureus
November 2024
Department of Orthopedics, Institute of Medical Sciences and SUM Hospital, Bhubaneswar, IND.
Introduction: This study aims to evaluate the effects of adjustable- and fixed-loop femoral endobuttons on intraoperative surgeon satisfaction and postoperative patient functional outcomes in anterior cruciate ligament (ACL) reconstruction. The use of cortical suspensory devices, either fixed-loop or adjustable-loop, is common in ACL reconstruction surgeries for femoral tunnel fixation. Fixed-loop devices, although effective, often require additional tunnel drilling, potentially leading to tunnel widening.
View Article and Find Full Text PDFKnee Surg Relat Res
December 2024
Department of Orthopedics, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan.
Background: Septic arthritis is a rare but devastating complication after anterior cruciate ligament reconstruction (ACLR). While early treatment can prevent significant graft complications, outcomes are often inferior to those in uncomplicated ACLR. Furthermore, whether to retain or remove the graft after infection remains debatable.
View Article and Find Full Text PDFBackground: The anterior cruciate ligament (ACL) is a vital structure in the knee responsible for preventing anterior translation; and countering rotational and valgus stress. The anteromedial and posterolateral bundles of the ACL, which are distinguished by their attachments at the tibia and femur, respectively, make up the ACL. The study is designed to evaluate the diagnostic parameters of lever sign in acute settings when compared against MRI as investigation of choice and compare them with the conventional tests.
View Article and Find Full Text PDFClin Orthop Surg
December 2024
Department of Orthopedic Surgery, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Seoul, Korea.
Background: To compare knee laxity between the conventional round tunnel and oval tunnel techniques in primary anterior cruciate ligament (ACL) reconstruction in a porcine knee model.
Methods: Twenty porcine knees were used for evaluating laxity in terms of anterior translation and anterolateral rotation. The study determined porcine knee kinematics on the Instron instruments under simulated Lachman (89 N anterior tibial load) at 15°, 30°, and 60° of flexion and a simulated pivot shift test (89 N anterior tibial load, 10 Nm valgus, and 4 Nm internal tibial torque) at 30° of flexion.
HSS J
July 2024
Department of Sports Medicine, Hospital for Special Surgery, New York, NY, USA.
Background: To improve outcomes following anterior cruciate ligament (ACL) reconstruction, bridge-enhanced ACL restoration (BEAR) was introduced. Bridge-enhanced ACL restoration uses a collagen-based implant saturated with infused autologous blood to bridge the torn proximal and distal ACL fibers.
Purpose: We sought to analyze the short-term complications, clinical outcomes, and patient-reported outcome measures (PROMs) in patients undergoing BEAR outside of the initial clinical trials.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!