The recent outbreaks of a lethal E. coli strain in Germany have aroused renewed interest in developing rapid, specific and accurate systems for detecting and characterizing bacterial pathogens in suspected contaminated food and/or water supplies. To address this need, we have designed, fabricated and tested an integrated modular-based microfluidic system and the accompanying assay for the strain-specific identification of bacterial pathogens. The system can carry out the entire molecular processing pipeline in a single disposable fluidic cartridge and detect single nucleotide variations in selected genes to allow for the identification of the bacterial species, even its strain with high specificity. The unique aspect of this fluidic cartridge is its modular format with task-specific modules interconnected to a fluidic motherboard to permit the selection of the target material. In addition, to minimize the amount of finishing steps for assembling the fluidic cartridge, many of the functional components were produced during the polymer molding step used to create the fluidic network. The operation of the cartridge was provided by electronic, mechanical, optical and hydraulic controls located off-chip and packaged into a small footprint instrument (1 ft(3)). The fluidic cartridge was capable of performing cell enrichment, cell lysis, solid-phase extraction (SPE) of genomic DNA, continuous flow (CF) PCR, CF ligase detection reaction (LDR) and universal DNA array readout. The cartridge was comprised of modules situated on a fluidic motherboard; the motherboard was made from polycarbonate, PC, and used for cell lysis, SPE, CF PCR and CF LDR. The modules were task-specific units and performed universal zip-code array readout or affinity enrichment of the target cells with both made from poly(methylmethacrylate), PMMA. Two genes, uidA and sipB/C, were used to discriminate between E. coli and Salmonella, and evaluated as a model system. Results showed that the fluidic system could successfully identify bacteria in <40 min with minimal operator intervention and perform strain identification, even from a mixed population with the target of a minority. We further demonstrated the ability to analyze the E. coli O157:H7 strain from a waste-water sample using enrichment followed by genotyping.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4386729 | PMC |
http://dx.doi.org/10.1039/c2lc40805h | DOI Listing |
Anal Chim Acta
November 2024
University of Natural Resources and Life Sciences, Vienna, Department of Chemistry, Institute of Analytical Chemistry, Muthgasse 18, 1190, Wien, Austria. Electronic address:
Background: Solid phase extraction (SPE) is a standard sample preparation technique in HPLC workflows. Inline cartridges are high-performance alternatives to manual or robotic systems but at long term, they suffer from irreversible sorption of matrix components and sorbent compaction. Bead injection (BI) is a niche fluidic technique that allows renewing a sorbent bed through the manipulation of its suspension.
View Article and Find Full Text PDFLab Chip
October 2024
Life Sciences Division, National Research Council of Canada (NRC), 75 de Mortagne Boulevard, Boucherville, QC, J4B 6Y4, Canada.
Droplet digital polymerase chain reaction (ddPCR) stands out as a highly sensitive diagnostic technique that is gaining traction in infectious disease diagnostics due to its ability to quantitate very low numbers of viral gene copies. By partitioning the sample into thousands of droplets, ddPCR enables precise and absolute quantification without relying on a standard curve. However, current ddPCR systems often exhibit relatively low levels of integration, and the analytical process remains dependent on elaborate workflows for up-front sample preparation.
View Article and Find Full Text PDFBiosens Bioelectron
November 2024
BioCIS, CNRS, Université Paris-Saclay, Orsay, 91400, France. Electronic address:
Surface-enhanced Raman Scattering (SERS) has become a powerful spectroscopic technology for highly sensitive detection. However, SERS is still limited in the lab because it either requires complicated preparation or is limited to specific compounds, causing poor applicability for practical applications. Herein, a micro-macro SERS strategy, synergizing polymer-assisted printed process with paper-tip enrichment process, is proposed to fabricate highly sensitive paper cartridges for sensitive practical applications.
View Article and Find Full Text PDFACS Sens
September 2024
Helia Biomonitoring, Eindhoven 5612 AR, The Netherlands.
Continuous biosensors measure concentration-time profiles of biomolecular substances in order to allow for comparisons of measurement data over long periods of time. To make meaningful comparisons of time-dependent data, it is essential to understand how measurement imprecision depends on the time interval between two evaluation points, as the applicable imprecision determines the significance of measured concentration differences. Here, we define a set of measurement imprecisions that relate to different sources of variation and different time scales, ranging from minutes to weeks, and study these using statistical analyses of measurement data.
View Article and Find Full Text PDFFront Chem
July 2024
Département de Radiopharmacologie, Ensemble Hospitalier de l'Institut Curie, Saint-Cloud, France.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!