Purpose: The braided polyblend (FiberWire) suture is recognized for its superiority in tensile strength in flexor tendon repair. The purpose of this study was to compare the biomechanical performance of 3 loop-suture materials used in a locking 6-strand flexor tendon repair configuration: braided polyblend (FiberLoop 4-0), cable nylon (Supramid Extra II 4-0), and braided polyester (Tendo-Loop 4-0). We hypothesized that, using this technique, the braided polyblend suture would give superior tensile strength compared with the other 2 suture materials.
Methods: We divided 30 fresh porcine flexor tendons transversely and repaired each with 1 of the 3 suture materials using a modified Lim-Tsai 6-strand suture technique. We loaded the repaired tendons to failure using a materials testing machine and collected data on the mechanism of failure, ultimate tensile strength, gap strength, and stiffness.
Results: Failure mechanisms for the repaired specimens were as follows: the braided polyblend had 50% suture breakage and 50% suture pullout; the cable nylon had 100% suture breakage; and the braided polyester had 80% suture breakage and 20% suture pullout. Specimens repaired with the braided polyblend suture had the highest mean ultimate tensile strength (97 N; standard deviation, 22) and the highest mean gap force (35 N; standard deviation, 7).
Conclusions: This study supports the findings of previous studies showing superior strength of the braided polyblend suture.
Clinical Relevance: We were able to achieve up to 124 N in ultimate tensile strength and 48 N of gap force with this suture in porcine tendons. This gives greater confidence in starting immediate controlled passive or active rehabilitation after repair of flexor tendon injuries.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jhsa.2012.06.008 | DOI Listing |
JSES Int
July 2023
Orthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA.
Clin Orthop Surg
June 2023
Orthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA.
Background: The purpose of this study was to quantify and compare the biomechanical characteristics of a new locking loop stitch (LLS), developed utilizing the concepts of both running locking stitch and needleless stitch, to the traditional Krackow stitch.
Methods: The Krackow stitch with No.2 braided suture and the LLS with 1.
Indian J Orthop
June 2023
Fort, Krishna Rajendra Road, Bangalore, 560002 India Department of Orthopaedics, Bangalore Medical College and Research Institute.
Background: Patellar fractures account for 1% of all skeletal injuries. Tension band wiring using SS wire has been the most commonly practiced procedure. Although this has shown good results, many patients experience hardware related problems like pain, irritation and prominence which necessitate it's removal.
View Article and Find Full Text PDFClin Orthop Relat Res
July 2022
Pan Am Clinic, Winnipeg, Manitoba, Canada.
Background: ACL graft-suture fixation can be constructed with needle or needleless techniques. Needleless techniques have the advantage of decreased injury, preparation time, and cost. The Nice knot is common among upper extremity procedures, and has been shown to have higher load to failure and less elongation compared with other double loop knots; however, there are no studies that have looked at its use for ACL graft-suture construct to determine whether it offers less elongation relative to other needleless techniques.
View Article and Find Full Text PDFJ Foot Ankle Surg
July 2021
Professor, Department of Orthopaedic Surgery, University of Cincinnati, Cincinnati, OH.
As sutures have progressed in strength, increasing evidence supports the suture tendon interface as the site where most tendon repairs fail. We hypothesized that suture tape would have a higher load to failure versus polyblend suture due to its larger surface area. Eleven matched pairs of cadaveric Achilles tendons were sutured with 2 mm wide braided ultrahigh molecular weight polyethylene tape (Tape) or 2 mm wide braided ultrahigh molecular weight polyethylene suture (Suture) using a Krackow repair method.