A defective aortic valve removed from a cadaver was installed on a testing unit imitating systemic circulation. The defect (insufficiency of the valve) was corrected by means of valvular devices consisting of a thin elastic membrane which was flat and round in one case and shaped like a spherical vault in the other; the devices were fastened on the distal end of a catheter. The authors present the values of pressure in the heart, aorta and coronary arteries and the minute circulation volume before and after correction of the defect. It is concluded that the suggested valvular devices are efficient and further study is expedient.

Download full-text PDF

Source

Publication Analysis

Top Keywords

aortic valve
8
testing unit
8
valvular devices
8
[use original
4
valve
4
original valve
4
devices
4
valve devices
4
devices catheter
4
catheter correction
4

Similar Publications

: New-onset postoperative atrial fibrillation (POAF) is the most common complication after cardiac surgery, occurring approximately in one-third of the patients. This study considered all-comer patients who underwent cardiac surgery to build a predictive model for POAF. : A total of 3467 (Center 1) consecutive patients were used as a derivation cohort to build the model.

View Article and Find Full Text PDF

Paravalvular leak (PVL) was initially recognized as one of the most common complications after transcatheter aortic valve implantation (TAVI) and has been linked to adverse clinical outcomes, including mortality. This study aims to assess the long-term clinical effects of PVL in patients undergoing TAVI with the latest generation of transcatheter aortic valves, as part of the national observational prospective multicenter study OBSERVANT II. OBSERVANT II included all consecutive patients with severe aortic stenosis who underwent TAVI across 28 Italian centers from December 2016 to September 2018.

View Article and Find Full Text PDF

Previous studies evaluated the prognostic role of hematological parameters in predicting outcome in patients with infective endocarditis (IE). However, only a few studies evaluated the role of hematological parameters in patients undergoing surgery for IE. The aim of this study was to review our 20-year experience with the treatment of native (NVE) and prosthetic (PVE) valve endocarditis and to evaluate the role of neutrophil-to-lymphocyte ratio (NLR), neutrophil-to-platelet ratio (NPR), platelet-to-lymphocyte ratio (PLR), monocyte-to-lymphocyte ratio (MLR), neutrophil-to monocyte ratio (NMR), and systemic inflammatory index (SII) on early and long-term outcomes of patients undergoing surgery for NVE and PVE.

View Article and Find Full Text PDF

Stuck prosthetic valves, often resulting from pannus formation or thrombus accumulation, represent a critical complication in prosthetic valve management, carrying significant risks for morbidity and mortality. This study aims to identify factors associated with stuck valve development and assess the effectiveness of interventions in restoring normal valve function. A total of 27 patients with stuck valves were analyzed, including mitral, aortic, and tricuspid valve cases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!