A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ultrasonication study for suspending single-walled carbon nanotubes in water. | LitMetric

A systematic calorimetry-based technique was developed to standardize single-walled carbon nanotube (SWNT) dispersion protocol. Simple calorimetric experiments were performed to benchmark the performance of the ultra-dismembrator. Temperature profiles for the sonication period were utilized to estimate energy input to the system. Energy loss profile was generated for the ultradismembrator in use and a calibration relationship was formulated that could standardize the sonication process. The standardized protocol was used to prepare aqueous SWNT suspensions-sonicating SWNTs in a varied range of input energy (18-100 kJ) in water. SWNT mass fractions suspended for each energy input was accurately measured and the suspended SWNT samples were characterized for morphology, surface potential, cluster size and structure, and chemical functionality using high resolution transmission electron microscopy (HRTEM), electrophoresis, dynamic and static light scattering (DLS/SLS), and Raman spectroscopy. The study demonstrated that suspended mass of SWNTs increased up to 18 kJ of energy input with no further increase upon continued energy input. The physicochemical properties showed similar trend for energy input. The aggregate cluster size, surface potential behavior, as well as the Raman defect properties plateaued after the initial energy input. The significant changes observed were limited to morphological properties, i.e., shorter length, debundled, and sharp edged SWNTs and fractal cluster formation (lower D(f)) with increased input energy.

Download full-text PDF

Source
http://dx.doi.org/10.1166/jnn.2012.6212DOI Listing

Publication Analysis

Top Keywords

energy input
24
energy
9
single-walled carbon
8
input
8
input energy
8
surface potential
8
cluster size
8
ultrasonication study
4
study suspending
4
suspending single-walled
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!