Microfluidic devices can provide unique control over both the chemoattractant gradient and the migration environment of the cells. Our work incorporates laser-machined micro and nanofluidic channels into bulk fused silica and cover slip-sized silica wafers. We have designed “open” chemotaxis devices that produce passive chemoattractant gradients without an external micropipette system. Since the migration area is unobstructed, cells can be easily loaded and strategically placed into the devices with a standard micropipette. The reusable monolithic glass devices have integral ports that can generate multiple gradients in a single experiment. We also used cover slip microfluidics for chemotaxis assays. Passive gradients elicited from these cover slips could be readily adapted for high throughput chemotaxis assays.We have also demonstrated for the first time that cells can be recruited into cover slip ports eliciting passive chemoattractant gradients. This proves, in principle, that intravital cover slip configurations could deliver controlled amounts of drugs, chemicals, or pathogens as well as recruit cells for proteomic or histological analysis in living animals while under microscopic observation. Intravital cover slip fluidics will create a new paradigm for in vivo observation of biological processes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3995343 | PMC |
http://dx.doi.org/10.1017/S1431927612000475 | DOI Listing |
Magn Reson Imaging
January 2025
Department of Radiology, People's Hospital of Xinjiang Uygur Autonomous Region, Urumqi, Xinjiang Uygur Autonomous Region, China. Electronic address:
3D BFFE and TRANCE can provide a visualization of pulmonary vessels without injection of contrast agent. T-SLIP can observe a large area of vessels using an arterial spin labeling technique. 3D BFFE and TRANCE with two T-SLIP placement strategies were compared on pulmonary artery imaging.
View Article and Find Full Text PDFBone Joint J
January 2025
Grampian Orthopaedics, Aberdeen Royal Infirmary, Aberdeen, UK.
Aims: The Exeter femoral stem has a cemented, polished taper-slip design, and an excellent track record. The current range includes short-length options for various offsets, but less is known about the performance of these stems. The aim of this study was to compare the survival of short-length stems with standard-length Exeter stems.
View Article and Find Full Text PDFTraffic Inj Prev
November 2024
ProBiomechanics LLC, Bloomfield Hills, Michigan.
Objective: The effect of shoulder-belt load-limiting was evaluated on right-front passenger kinematics in 90 km/h oblique OMDB (offset moving deformable barrier) impacts and compared to kinematics in 56 km/h NCAP crash tests. The study focused on the influence of webbing pulling out of the retractor increasing forward excursion of the upper torso and head.
Methods: 18 OMDB crash tests were conducted by NHTSA at 90 km/h.
Heliyon
November 2024
Department of Civil Engineering, Military Institute of Science and Technology (MIST), Dhaka, Bangladesh.
The pertinence of recycled brick aggregate (RBA) in concrete structures largely depends on their bonding ability with the rebars. Considering the practical detailing of concrete structures where main rebars are usually confined by stirrups, this study conducted bending pullout tests on 12 beam specimens to study the influence of concrete confinement on the bond behavior of rebar in RBA concrete. The investigated variables include RBA%, rebar diameter (), embedment length ( ), and the ratio of concrete cover to rebar diameter ().
View Article and Find Full Text PDFJ Vis Exp
September 2024
School of Life Sciences, Guangzhou University;
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!