Background: Evaluations of the effectiveness of air pollution policy interventions are scarce. This study investigated air pollution at street level before and after implementation of local traffic policies including low emission zones (LEZ) directed at heavy duty vehicles (trucks) in five Dutch cities.

Methods: Measurements of PM(10), PM(2.5), 'soot', NO(2), NO(x), and elemental composition of PM(10) and PM(2.5) were conducted simultaneously at eight streets, six urban background locations and four suburban background locations before (2008) and two years after implementation of the policies (2010). The four suburban locations were selected as control locations to account for generic air pollution trends and weather differences.

Results: All pollutant concentrations were lower in 2010 than in 2008. For traffic-related pollutants including 'soot' and NO(x) and elemental composition (Cr, Cu, Fe) the decrease did not differ significantly between the intervention locations and the suburban control locations. Only for PM(2.5) reductions were considerably larger at urban streets (30%) and urban background locations (27%) than at the matching suburban control locations (20%). In one urban street where traffic intensity was reduced with 50%, 'soot', NO(x) and NO(2) concentrations were reduced substantially more (41, 36 and 25%) than at the corresponding suburban control location (22, 14 and 7%).

Conclusion: With the exception of one urban street where traffic flows were drastically reduced, the local traffic policies including LEZ were too modest to produce significant decreases in traffic-related air pollution concentrations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2012.06.089DOI Listing

Publication Analysis

Top Keywords

air pollution
20
local traffic
12
traffic policies
12
background locations
12
control locations
12
suburban control
12
low emission
8
emission zones
8
pollution concentrations
8
policies including
8

Similar Publications

Introduction: Short-term exposure to air pollution may worsen the course of ischemic heart disease (IHD), causing acute and chronic coronary syndromes.

Objectives: This study aimed to assess the risk of hospital admission due to chronic and acute coronary syndromes (ACS) after exposure to various air pollutants in Poland.

Methods: In this time-series study, the risk of hospital admission due to IHD over 3 days from exposure to several air pollutants was evaluated.

View Article and Find Full Text PDF

Enhancing Droplet Spreading on a Hydrophobic Plant Surface by Surfactant/Cellulose Nanocrystal Complexes.

ACS Nano

January 2025

Department of Chemical Engineering, Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.

A surfactant is an efficient and common additive used to enhance the spreading of droplets on hydrophobic surfaces. However, a high surfactant concentration is required to achieve the desired performance, resulting in environmental pollution and increased costs. Additionally, the pesticide loading capacity of surfactants at low concentrations (below their critical micelle concentrations) is a concern.

View Article and Find Full Text PDF

Atmospheric Deposition of Microplastics in South Central Appalachia in the United States.

ACS EST Air

January 2025

Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States.

Due to the increased prevalence of plastic pollution globally, atmospheric deposition of microplastics (MPs) is a significant issue that needs to be better understood to identify potential consequences for human health. This study is the first to quantify and characterize atmospheric MP deposition in the Eastern United States. Passive sampling was conducted at two locations within the Eastern United States, specifically in remote South Central Appalachia, from March to September 2023.

View Article and Find Full Text PDF

Spatiotemporal Mapping of Ultrafine Particle Fluxes in an Office HVAC System with a Diffusion Charger Sensor Array.

ACS EST Air

January 2025

Lyles School of Civil & Construction Engineering, Purdue University, West Lafayette, Indiana 47907, United States.

Commercial HVAC systems intended to mitigate indoor air pollution are operated based on standards that exclude aerosols with smaller diameters, such as ultrafine particles (UFPs, D ≤ 100 nm), which dominate a large proportion of indoor and outdoor number-based particle size distributions. UFPs generated from occupant activities or infiltrating from the outdoors can be recirculated and accumulate indoors when they are not successfully filtered by an air handling unit. Monitoring UFPs in real occupied environments is vital to understanding these source and mitigation dynamics, but capturing their rapid transience across multiple locations can be challenging due to high-cost instrumentation.

View Article and Find Full Text PDF

Background: Air pollution is a significant environmental risk factor for cardiovascular diseases (CVDs), but its impact on African populations is under-researched due to limited air quality data and health studies.

Objectives: The purpose of this study was to synthesize available research on the effects of air pollution on CVDs outcomes in African populations, identify knowledge gaps, and suggest areas for research and policy intervention.

Methods: A systematic search of PubMed was conducted using terms capturing criteria ambient air pollutants (for example particulate matter, nitrogen dioxide, ozone, and sulfur dioxide) and CVDs and countries in Africa.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!