Mutual information (MI) is a well-accepted similarity measure for image registration in medical systems. However, MI-based registration faces the challenges of high computational complexity and a high likelihood of being trapped into local optima due to an absence of spatial information. In order to solve these problems, multi-scale frameworks can be used to accelerate registration and improve robustness. Traditional Gaussian pyramid representation is one such technique but it suffers from contour diffusion at coarse levels which may lead to unsatisfactory registration results. In this work, a new multi-scale registration framework called edge preserving multiscale registration (EPMR) was proposed based upon an edge preserving total variation L1 norm (TV-L1) scale space representation. TV-L1 scale space is constructed by selecting edges and contours of images according to their size rather than the intensity values of the image features. This ensures more meaningful spatial information with an EPMR framework for MI-based registration. Furthermore, we design an optimal estimation of the TV-L1 parameter in the EPMR framework by training and minimizing the transformation offset between the registered pairs for automated registration in medical systems. We validated our EPMR method on both simulated mono- and multi-modal medical datasets with ground truth and clinical studies from a combined positron emission tomography/computed tomography (PET/CT) scanner. We compared our registration framework with other traditional registration approaches. Our experimental results demonstrated that our method outperformed other methods in terms of the accuracy and robustness for medical images. EPMR can always achieve a small offset value, which is closer to the ground truth both for mono-modality and multi-modality, and the speed can be increased 5-8% for mono-modality and 10-14% for multi-modality registration under the same condition. Furthermore, clinical application by adaptive gross tumor volume re-contouring for clinical PET/CT image-guided radiation therapy throughout the course of radiotherapy is also studied, and the overlap between the automatically generated contours for the CT image and the contours delineated by the oncologist used for the planning system are on average 90%.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/57/16/5187DOI Listing

Publication Analysis

Top Keywords

registration medical
12
edge preserving
12
scale space
12
registration
11
multiscale registration
8
medical images
8
based edge
8
image-guided radiation
8
radiation therapy
8
medical systems
8

Similar Publications

Importance: During buprenorphine treatment for opioid use disorder (OUD), risk factors for opioid relapse or treatment dropout include comorbid substance use disorder, anxiety, or residual opioid craving. There is a need for a well-powered trial to evaluate virtually delivered groups, including both mindfulness and evidence-based approaches, to address these comorbidities during buprenorphine treatment.

Objective: To compare the effects of the Mindful Recovery Opioid Use Disorder Care Continuum (M-ROCC) vs active control among adults receiving buprenorphine for OUD.

View Article and Find Full Text PDF

Importance: Trials have not demonstrated superiority of alteplase or tenecteplase vs standard care in patients with mild stroke and have raised safety concerns. Prourokinase is an alternative fibrinolytic that may have a favorable safety profile, and the benefit-risk profile of prourokinase in mild stroke is unknown.

Objective: To investigate the efficacy and safety of prourokinase in mild ischemic stroke within 4.

View Article and Find Full Text PDF

Introduction And Hypothesis: Measuring changes in the vaginal pressure profile (VPP) with the Femfit® by JUNOFEM during various sports will help improve understanding of the magnitude of pressures generated during such activities and the pelvic floor's response to those pressures. This could aid in selecting safe exercises for women with pelvic floor dysfunction. The primary aim of this study was to measure intravaginal pressure changes using a novel pressure sensor array (Femfit®) during high-risk sports activities in elite female athletes with and without stress urinary incontinence (SUI).

View Article and Find Full Text PDF

exon 14 ex14) skipping occurs in 3-4% of non-small-cell lung cancer (NSCLC) cases. Low frequency of this alteration necessitated open-label, single-arm trials to investigate MET inhibitors. Since broad MET biomarker testing was only recently introduced in many countries, there is a lack of historical real-world data from patients with ex14 skipping NSCLC receiving conventional therapies.

View Article and Find Full Text PDF

Contrast-enhanced US of High-Risk Indeterminate Focal Liver Observations Categorized as LR-4 or LR-M at CT/MRI.

Radiology

January 2025

From the Department of Radiology, Thomas Jefferson University Hospital, 132 S 10th St, 763G Main Bldg, Philadelphia, PA 19107 (A.L., C.K.Y.E., T.S.X., S.K.R., C.E.W., K.B., J.R.E., F.F.); Division of Internal Medicine, Hepatobiliary and Immunoallergic Diseases, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy (F.P.); Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy (F.P.); University of California San Diego, San Diego, Calif (Y.K.); University of Calgary, Calgary, Canada (A.M.K., S.R.W.); Einstein Medical Center, Philadelphia, Pa (S.K.R.); Vanderbilt University, Nashville, Tenn (V.P.); Stanford University, Stanford, Calif (A.K.); UT Southwestern Medical Center, Dallas, Tex (D.T.F.); Department of Visceral Surgery and Medicine, Bern University Hospital, University of Bern, Bern, Switzerland (A.B., I.P.R.); Department of Imaging Sciences, School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, United Kingdom (P.S.S.); and Department of Radiology, King's College Hospital, London, United Kingdom (P.S.S.).

Background Indeterminate focal liver observations in patients at risk for hepatocellular carcinoma (HCC) may require invasive biopsy or follow-up, which could lead to delays in definitive categorization and to postponement of treatment. Purpose To examine clinical effect of contrast-enhanced US (CEUS) in participants with high-risk indeterminate liver observations categorized as Liver Imaging Reporting and Data System (LI-RADS) category LR-4 (probably HCC) or LI-RADS category LR-M (probably or definitely malignant but not HCC specific) at CT or MRI. Materials and Methods This was a secondary analysis of a prospective international multicenter validation study for CEUS LI-RADS (January 2018 to August 2021).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!