Context: Clinical and laboratory studies regarding performance of recently introduced luting cements: Adhesive resin cement and resin-modified glass ionomer cement (GIC), are limited.

Aims: To compare the retention and marginal seating of Ni-Cr alloy restorations using newer luting cements: Resin-modified GIC and adhesive resin cement with those of the oldest cement, zinc phosphate.

Materials And Methods: Thirty maxillary premolars of similar sizes were prepared to receive cast metal copings. Copings were placed on the prepared teeth and the marginal opening was examined using a Nikon Measuroscope. The specimens were randomly assigned to three groups. Group I castings were luted with zinc phosphate, Group II castings luted with resin-modified GIC, and Group III castings luted with adhesive resin cement. After cementation marginal seating was measured. Tensile loads required to dislodge the crowns were obtained using MTS machine.

Statistical Analysis Used: Tukey's test, Analysis of Variance (ANOVA).

Results: For zinc phosphate cement, mean marginal seating was 31 microns. Mean retentive strength was 287 Newtons. For resin-modified GIC, mean marginal seating was 29.6 microns. Mean retentive strength was 610 Newtons. For adhesive resin cement, mean marginal seating was 49 microns. Mean retentive strength was 613 Newtons.

Conclusions: Marginal seating of adhesive resin cement was significantly greater than that of zinc phosphate and resin-modified GIC. Retentive strength of adhesive resin cement and resin-modified GIC was significantly greater than that of zinc phosphate There was no significant difference of retentive strength between adhesive resin cement and resin-modified GIC.

Download full-text PDF

Source
http://dx.doi.org/10.4103/0970-9290.99032DOI Listing

Publication Analysis

Top Keywords

marginal seating
28
adhesive resin
28
resin cement
28
resin-modified gic
24
retentive strength
20
zinc phosphate
16
luting cements
12
cement resin-modified
12
castings luted
12
microns retentive
12

Similar Publications

This study aimed to evaluate the scanning time and marginal fit of CAD/CAM crowns fabricated using different intraoral scanning systems (IOS) (O1-Omnicam 1.0, O2-Omnicam 2.0, PS-Primescan).

View Article and Find Full Text PDF

Background: Laparoscopic parenchyma-sparing hepatectomy (PSH) is an effective treatment for colorectal liver metastases (CRLMs), but ensuring the safety and radicality of the procedure, particularly for deep-seated tumors, remains challenging. Surgical navigation technologies such as augmented reality navigation (ARN) and indocyanine green fluorescence imaging (ICG-FI) are increasingly utilized to guide surgery, yet their efficacy for CRLMs is unclear. This study aims to evaluate the short- and long-term outcomes of ARN combined with ICG-FI-guided (ARN-FI) laparoscopic PSH for CRLMs.

View Article and Find Full Text PDF

Complete hepatic caudate lobe resection: is robotic approach safe? Report from experienced centers.

J Robot Surg

December 2024

Hepato-Biliary and Pancreatic Surgery Unit, Department of Surgery, Hospital del Mar, Pompeu Fabra University, Barcelona, Spain.

Minimally invasive liver surgery has become widely accepted as a safe and effective approach, especially with experienced surgeons. Robotic hepatectomy may offer significant benefits in challenging procedures like caudate lobe resection. The caudate lobe's intricate anatomy and deep-seated location make its resection particularly challenging, with limited reports on minimally invasive techniques.

View Article and Find Full Text PDF

Undifferentiated pleomorphic sarcoma (UPS) is an uncommon and aggressive soft tissue tumor primarily affecting older adults, often presenting as a rapidly enlarging, painless mass in the extremities or other deep-seated locations. This case involves a 55-year-old woman who experienced a rapidly progressive and painful swelling in her right thigh following trauma. Imaging studies identified a large, lobulated tumor in the adductor muscles, close to the femur and pubic ramus, with no bone involvement or evidence of distant metastasis.

View Article and Find Full Text PDF

Introduction: With the current surge into digital dentistry, several options are available for clinicians, for example, when providing indirect restorations. There is a need for evidence on the quality of fixed dental prostheses (FDPs) fabricated using either digital or conventional impressions. This study aimed to evaluate the marginal fit of single-crown and three-unit FDP frameworks fabricated from digital and conventional impressions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!