We evaluated, by an improved susceptibility testing method, the prevalence and significance of low-level glycopeptide resistance in methicillin-resistant Staphylococcus aureus (MRSA) isolates, which belonged to a previously described, retrospective cohort of patients treated for orthopedic device-related infections (ODRI) at the Geneva University Hospital between 2000 and 2008. Fifty-seven individual or multiple isolates were retrieved from 41 ODRI patients for glycopeptide susceptibility and clonality studies, including 20 patients with prosthetic joint (PJ) and 21 with osteosynthesis (OS) MRSA infections. Low-level glycopeptide resistance was detected by elevated teicoplanin or/and vancomycin minimum inhibitory concentrations (MICs ≥ 4 mg/L), as determined by a previously validated combination of macrodilution and agar dilution assays of improved sensitivity. MRSA isolates with elevated teicoplanin MICs were detected in 20/41 (49 %) ODRI patients at the onset or during the course of glycopeptide therapy, namely, in 10 of 20 patients with PJ and 10 of 21 patients with OS infections. Only one isolate developed a concomitant increase in vancomycin MIC during therapy. 13/20 (65 %) glycopeptide-intermediate S. aureus (GISA)-infected patients, including 7/10 (70 %) with PJ and 6/10 (60 %) with OS, experienced treatment failure. In contrast, therapy failed in only 5/21 (24 %) ODRI patients with non-GISA isolates (p = 0.012), including 2/10 (20 %) with PJ and 3/11 (27 %) with OS infections. The emergence of low-level teicoplanin resistance could not be explained by teicoplanin administration, since only four patients received teicoplanin. The evaluation of low-level teicoplanin resistance may improve the detection of GISA isolates. Further studies are warranted to evaluate the impact of low-level teicoplanin resistance on the outcome of glycopeptide therapy.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10096-012-1705-8DOI Listing

Publication Analysis

Top Keywords

odri patients
12
low-level teicoplanin
12
teicoplanin resistance
12
patients
9
glycopeptide susceptibility
8
orthopedic device-related
8
device-related infections
8
methicillin-resistant staphylococcus
8
staphylococcus aureus
8
low-level glycopeptide
8

Similar Publications

Article Synopsis
  • Rifampicin is an important antibiotic used to treat infections caused by staphylococci that form biofilms, especially in patients with orthopedic devices.
  • A pilot study showed that patients treated with rifampicin for these infections developed staphylococci strains resistant to rifampicin during treatment.
  • This antibiotic resistance persisted in patients for up to 2 months after they stopped taking rifampicin.
View Article and Find Full Text PDF

The use of a tibial stem in primary total knee arthroplasty for patients with a frontal deformity of more than ten degrees reduces the rate of postoperative pain.

Eur J Orthop Surg Traumatol

August 2024

Service de Chirurgie Orthopédique et Traumatologique, Hôpital Lariboisière, 2 rue Ambroise Paré, 75010, Paris, France.

Background: The use of a tibial stem for large deformities (> 10°) would reduce the incidence of pain. The aim of this study was to compare the effect of tibial stem on postoperative pain and aseptic loosening at the tibia in patients with a preoperative deformity > 10° in the frontal plane at 2 years follow-up.

Methods: This was a retrospective single-center case-control study.

View Article and Find Full Text PDF

Glucocorticoids may be given prior to major orthopedic surgery to decrease postoperative nausea, vomiting, and pain. Additionally, many orthopedic patients may be on chronic glucocorticoid therapy. The aim of our study was to investigate whether glucocorticoid administration influences Orthopedic-Device-Related Infection (ODRI) in a rat model.

View Article and Find Full Text PDF

Introduction: Extra-articular hip resection may be necessary in cases of malignant tumour of the pelvic bone or of the proximal femur invading the hip joint. When the tumour is in the proximal femur, it is possible to resect the acetabulum en bloc by performing a periacetabular osteotomy, but this creates a discontinuity in the pelvic ring with difficult reconstruction and diminished function. Several techniques described recently seek to be as sparing as possible on the pelvic bone by preserving the posterior column or both columns in order to facilitate reconstruction and improve function.

View Article and Find Full Text PDF

Orthopedic device-related infection (ODRI) poses a significant threat to patients with titanium-based implants. The challenge lies in developing antibacterial surfaces that preserve the bulk mechanical properties of titanium implants while exhibiting characteristics similar to bone tissue. In response, we present a two-step approach: silver nanoparticle (AgNP) coating followed by selective laser-assisted surface alloying on commonly used titanium alumina vanadium (TiAl6V4) implant surfaces.