A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Towards task-based assessment of CT performance: system and object MTF across different reconstruction algorithms. | LitMetric

Purpose: To investigate a measurement method for evaluating the resolution properties of CT imaging systems across reconstruction algorithms, dose, and contrast.

Methods: An algorithm was developed to extract the task-based modulation transfer function (MTF) from disk images generated from the rod inserts in the ACR phantom (model 464 Gammex, WI). These inserts are conventionally employed for HU accuracy assessment. The edge of the disk objects was analyzed to determine the edge-spread function, which was differentiated to yield the line-spread function and Fourier-transformed to generate the object-specific MTF for task-based assessment, denoted MTF(Task). The proposed MTF measurement method was validated against the conventional wire technique and further applied to measure the MTF of CT images reconstructed with an adaptive statistical iterative algorithm (ASIR) and a model-based iterative (MBIR) algorithm. Results were further compared to the standard filtered back projection (FBP) algorithm. Measurements were performed and compared across different doses and contrast levels to ascertain the MTF(Task) dependencies on those factors.

Results: For the FBP reconstructed images, the MTF(Task) measured with the inserts were the same as the MTF measured from the wire-based method. For the ASIR and MBIR data, the MTF(Task) using the high contrast insert was similar to the wire-based MTF and equal or superior to that of FBP. However, results for the MTF(Task) measured using the low-contrast inserts, the MTF(Task) for ASIR and MBIR data was lower than for the FBP, which was constant throughout all measurements. Similarly, as a function of mA, the MTF(Task) for ASIR and MBIR varied as a function of noise--with MTF(Task) being proportional to mA. Overall greater variability of MTF(Task) across dose and contrast was observed for MBIR than for ASIR.

Conclusions: This approach provides a method for assessing the task-based MTF of a CT system using conventional and iterative reconstructions. Results demonstrated that the object-specific MTF can vary as a function of dose and contrast. The analysis highlighted the paradigm shift for iterative reconstructions when compared to FBP, where iterative reconstructions generally offer superior noise performance but with varying resolution as a function of dose and contrast. The MTF(Task) generated by this method is expected to provide a more comprehensive assessment of image resolution across different reconstruction algorithms and imaging tasks.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.4725171DOI Listing

Publication Analysis

Top Keywords

reconstruction algorithms
12
asir mbir
12
dose contrast
12
iterative reconstructions
12
mtftask
10
mtf
9
task-based assessment
8
measurement method
8
object-specific mtf
8
mtftask measured
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!