AI Article Synopsis

  • The study investigated the UV-Visible absorption spectra of malachite green in varying pH levels (7-11) and ethanol concentrations (45%-85%), revealing a maximum absorption wavelength at 620 nm and effective standard curve creation.
  • Using a low power trench-type ultrasound, the experiment compared the absorption of malachite green solutions under ultrasound and non-ultrasound conditions to measure the impact of hydroxyl free radical oxidation on degradation.
  • The method showed a detection limit of 8.4 x 10(-6) mmol x L(-1) with high testing precision and good reproducibility, making it suitable for fast detection of hydroxyl free radicals in ethanol solutions, particularly as malachite green is sensitive to heat

Article Abstract

Under the condition of different pH (7-11) and different ethanol volume fraction (45% to 85%), the ultraviolet-visible absorption spectra of malachite green were studied in neutral and alkaline ethanol solution, the maximum absorption wavelength at 620 nm was found, and the matching degree of standard curve was better established. In low power trench-type ultrasound apparatus, the absorption of the malachite green solution was measured under ultrasound and non-ultrasound, respectively. the difference values of the ultraviolet absorption of the malachite green solution under low power trench-type ultrasound were measured results of the hydroxyl free radical oxidation degrading malachite green, therefore hydroxyl free radical from low power trench-type ultrasound was determined indirectly. Then the contents of hydroxyl free radical in four conditions were measured. The detection limit of the method of 8.4 x 10(-6) mmol x L(-1) and the relative standard deviation of the method of 9.4 x 10(-5) - 3.7 x 10(-4) mmol x L(-1) were determined, a higher testing precision and good reproducibility were confirmed. It can be applied for fast detection of neutral and alkaline ethanol solution system in the case of very low concentration of hydroxyl free radicals. Since malachite green is heat sensitive, so compared to measuring temperature, the method possessed better functions for thermal effects of ultrasound.

Download full-text PDF

Source

Publication Analysis

Top Keywords

hydroxyl free
20
malachite green
20
free radical
16
low power
16
power trench-type
16
trench-type ultrasound
12
radical low
8
neutral alkaline
8
alkaline ethanol
8
ethanol solution
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!