A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Inhibitory effects of carbon dioxide insufflation on pneumoperitoneum and bowel distension after percutaneous endoscopic gastrostomy. | LitMetric

Aim: To evaluate the inhibitory effects of carbon dioxide (CO(2)) insufflation on pneumoperitoneum and bowel distension after percutaneous endoscopic gastrostomy (PEG).

Methods: A total of 73 consecutive patients who were undergoing PEG were enrolled in our study. After eliminating 13 patients who fitted our exclusion criteria, 60 patients were randomly assigned to either CO(2) (30 patients) or air insufflation (30 patients) groups. PEG was performed by pull-through technique after three-point fixation of the gastric wall to the abdominal wall using a gastropexy device. Arterial blood gas analysis was performed immediately before and after the procedure. Abdominal X-ray was performed at 10 min and at 24 h after PEG to assess the extent of bowel distension. Abdominal computed tomography was performed at 24 h after the procedure to detect the presence of pneumoperitoneum. The outcomes of PEG for 7 d post-procedure were also investigated.

Results: Among 30 patients each for the air and the CO(2) groups, PEG could not be conducted in 2 patients of the CO(2) group, thus they were excluded. Analyses of the remaining 58 patients showed that the patients' backgrounds were not significantly different between the two groups. The elevation values of arterial partial pressure of CO(2) in the air group and the CO(2) group were 2.67 mmHg and 3.32 mmHg, respectively (P = 0.408). The evaluation of bowel distension on abdominal X ray revealed a significant decrease of small bowel distension in the CO(2) group compared to the air group (P < 0.001) at 10 min and 24 h after PEG, whereas there was no significant difference in large bowel distension between the two groups. Pneumoperitoneum was observed only in the air group but not in the CO(2) group (P = 0.003). There were no obvious differences in the laboratory data and clinical outcomes after PEG between the two groups.

Conclusion: There was no adverse event associated with CO(2) insufflation. CO(2) insufflation is considered to be safer and more comfortable for PEG patients because of the lower incidence of pneumoperitoneum and less distension of the small bowel.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3400858PMC
http://dx.doi.org/10.3748/wjg.v18.i27.3565DOI Listing

Publication Analysis

Top Keywords

bowel distension
24
co2 group
16
co2 insufflation
12
air group
12
co2
10
patients
9
inhibitory effects
8
effects carbon
8
carbon dioxide
8
insufflation pneumoperitoneum
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!