Background: Super slim cigarettes are a relatively new type of cigarette in Canada, and an analysis of select toxicants in the mainstream smoke emissions of the super slim cigarette was conducted.
Method: The yields of selected toxicants in the mainstream smoke emissions of six brands of super slim cigarettes were compared with the Canadian Benchmark, which represents the cigarette designs most commonly found in Canada. A super slim cigarette was also compared with a 'Reference Cigarette' to study the impact of the significantly reduced circumference on mainstream smoke emissions.
Results: Compared with the Canadian Benchmark, the yields of carbon monoxide, the carbonyls, volatiles and the aromatic amines were significantly lower for the super slim cigarette, but the yields of formaldehyde and ammonia were significantly higher. For brands containing a mixed tobacco blend, the yields of tobacco-specific nitrosamines were increased significantly. The reduced circumference of the super slim cigarette resulted in a lower tobacco weight, which together with filter ventilation resulted in lower yields of many toxicants. However, the reduced circumference increased significantly the yields of formaldehyde and phenols in mainstream smoke emissions.
Conclusions: The notably slimmer design of the super slim cigarette resulted in lower yields of some toxicants in the mainstream smoke emissions. However, there were also significant increases in some toxicant levels in the mainstream smoke emissions including formaldehyde, ammonia and the phenols. There are no changes in emission levels that have been shown to reduce exposure or risk in a way that is meaningful, and therefore, the super slim cigarette should not be considered a 'less harmful' cigarette.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/tobaccocontrol-2012-050450 | DOI Listing |
Cureus
May 2024
Department of Gastroenterology, Chiba University, Chiba, JPN.
Endoscopic ultrasound-guided hepaticogastrostomy is performed when transpapillary biliary drainage using endoscopic retrograde cholangiopancreatography is difficult due to surgically altered anatomy, an inaccessible papilla, or difficult biliary cannulation. This procedure consists of puncturing the intrahepatic bile duct from the stomach, inserting a guidewire into the bile duct, dilating the puncture tract, and placing a stent. Recently, a novel partially covered self-expandable metal stent with a super-slim stent delivery system of 5.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
November 2023
Fujian Provincial Key Laboratory of Soil Environmental Health and Regulation, College of Resources and Environment, Fujian Agriculture and Forestry University, Fuzhou, 350002, China.
Extensive study on renewable energy storage has been sparked by the growing worries regarding global warming. In this study, incorporating the latest advancements in microbial electrochemistry and electrochemical CO reduction, a super-fast charging biohybrid battery was introduced by using pure formic acid as an energy carrier. CO electrolyser with a slim-catholyte layer and a solid electrolyte layer was built, which made it possible to use affordable anion exchange membranes and electrocatalysts that are readily accessible.
View Article and Find Full Text PDFInt J Cardiol
November 2023
Adult Congenital Heart Centre and National Centre for Pulmonary Hypertension, Royal Brompton & Harefield NHS Trust, London, UK; National Heart and Lung Institute, Imperial College, London, UK; Department of Medical Rehabilitation, Medical Faculty, University of Rijeka, Croatia. Electronic address:
Materials (Basel)
April 2023
School of Mechanical Engineering, Shandong University of Technology, Zibo 255049, China.
The internal wall of cardiovascular stent tubing produced by a drawing process has defects such as pits and bumps, making the surface rough and unusable. In this research, the challenge of finishing the inner wall of a super-slim cardiovascular stent tube was solved by magnetic abrasive finishing. Firstly, a spherical CBN magnetic abrasive was prepared by a new method, plasma molten metal powders bonding with hard abrasives; then, a magnetic abrasive finishing device was developed to remove the defect layer from the inner wall of ultrafine long cardiovascular stent tubing; finally, response surface tests were performed and parameters were optimized.
View Article and Find Full Text PDFFront Rehabil Sci
November 2022
WearME Lab, Department of Electrical and Computer Engineering, Western University, London, ON, Canada.
Twisted coiled actuators (TCAs) are promising artificial muscles for wearable soft robotic devices due to their biomimetic properties, inherent compliance, and slim profile. These artificial muscles are created by super-coiling nylon thread and are thermally actuated. Unfortunately, their slow natural cooling rate limits their feasibility when used in wearable devices for upper limb rehabilitation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!