Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: This prospective longitudinal study compared clinical and radiologic outcomes of total shoulder arthroplasty (TSA) using 3 different prosthetic designs, the Neer II system, the Bigliani-Flatow (BF), and a stemless prosthesis, the Total Evolutive Shoulder System (TESS).
Materials And Methods: Patients with advanced osteoarthritis of the glenohumeral joint who underwent TSA were followed up for 2 years. Four patient-oriented disability outcomes were used. The clinical data collected before surgery and at follow-up assessments during a 2-year period included active range of motion (ROM) in 6 directions and strength. Radiographic signs of glenoid and humeral component loosening were recorded. The incidence of humeral head subluxation was documented.
Results: Seventy-four patients completed the study. There was a significant improvement in the 4 disability measures, ROM, and strength at 2 years in all 3 groups (P < .0001). Active external rotation at 90° abduction was statistically significantly lower in the Neer II group (P = .001). The incidence of lucent lines around the glenoid component was higher in the Neer II group (P = .0002). No statistically significant relationship was seen between type of prosthesis and patient satisfaction (P > 0.05).
Conclusions: The 3 types of TSA prostheses used in this study all provided significant improvement in pain and function and were associated with high patient satisfaction. The Neer II was associated with less active external rotation and more lucent lines.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jse.2012.04.016 | DOI Listing |