A reversed phase (RP)-LC method using a C(18) column resistant to basic pH and an alkaline (pH 10) aqueous mobile phase was developed and coupled to MS with an electrospray ionization (ESI) source in the positive ion mode which provides MS(n) capability. In total, 26 impurities were detected in a commercial sample. The structures of the impurities were proposed based on comparison of their fragmentation patterns with those of the available reference substances, the synthetic route and literature data. Starting material and its residual impurities, intermediates, synthetic by-products and degradation products were the main sources of those impurities. 14 impurities described in this work were newly identified.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jpba.2012.06.041 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!