Purpose: To evaluate which mathematical model (monoexponential, biexponential, statistical, kurtosis) fits best to the diffusion-weighted signal in prostate magnetic resonance imaging (MRI).

Materials And Methods: 24 prostate 3-T MRI examinations of young volunteers (YV, n=8), patients with biopsy proven prostate cancer (PC, n=8) and an aged matched control group (AC, n=8) were included. Diffusion-weighted imaging was performed using 11 b-values ranging from 0 to 800 s/mm(2).

Results: Monoexponential apparent diffusion coefficient (ADC) values were significantly (P<.001) lower in the peripheral (PZ) zone (1.18±0.16 mm(2)/s) and the central (CZ) zone (0.73±0.13 mm(2)/s) of YV compared to AC (PZ 1.92±0.17 mm(2)/s; CZ 1.35±0.21 mm(2)/s). In PC ADC(mono) values (0.61±0.06 mm(2)/s) were significantly (P<.001) lower than in the peripheral of central zone of AC. Using the statistical analysis (Akaike information criteria) in YV most pixels were best described by the biexponential model (82%), the statistical model, respectively kurtosis (93%) each compared to the monoexponential model. In PC the majority of pixels was best described by the monoexponential model (57%) compared to the biexponential model.

Conclusion: Although a more complex model might provide a better fitting when multiple b-values are used, the monoexponential analyses for ADC calculation in prostate MRI is sufficient to discriminate prostate cancer from normal tissue using b-values ranging from 0 to 800 s/mm(2).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mri.2012.04.025DOI Listing

Publication Analysis

Top Keywords

comparison mathematical
4
mathematical models
4
models diffusion-weighted
4
prostate
4
diffusion-weighted prostate
4
prostate imaging
4
imaging purpose
4
purpose evaluate
4
evaluate mathematical
4
mathematical model
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!