Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
During the "Standards Development and International Harmonization: AOAC INTERNATIONAL Mid-Year Meeting" held on June 29, 2011, an Expert Review Panel (ERP) on behalf of AOAC INTERNATIONAL adopted the method "Simultaneous Determination of Vitamins D2 and D3 by LC-MS/MS in Infant Formula and Adult Nutritionals" as an AOAC Official First Action method. Vitamins D2 and D3 are extracted from the sample using pentane-ether; the extract is collected and dried under nitrogen. Vitamin D is separated from interfering compounds using UPLC, and quantitated using tandem mass spectrometry (MS/MS). Preliminary data showed the intermediate precision ranged from 3.34-8.05% and an accuracy range of 98.5-111% over the samples tested for vitamin D3. For vitamin D2, the intermediate precision ranged from 2.37-5.45% and accuracy ranged from 96.4-104% over the four matrixes evaluated. The analytical range for the method is bounded by the concentrations of the working standards, 21-270 ng/mL, and is equivalent to 0.168-2.16 mcg/100 g in ready-to-feed product. The practical method quantitation limit is 0.168 mcg/100 g product with method detection limit of 60 ng/100 g product. The ERP reviewed the data and determined that the performance characteristics of the method met the standard method performance requirements, and therefore the method was granted First Action status.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5740/jaoacint.cs2011_13 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!