Biodegradation property of beta-tricalcium phosphate-collagen composite in accordance with bone formation: a comparative study with Bio-Oss Collagen® in a rat critical-size defect model.

Clin Implant Dent Relat Res

President, Implant and Tissue Engineering Dental Network-Tokyo, Tokyo, Japan; associate professor, Implantology and Periodontics, New York University College of Dentistry, NY, USA; professor and chair, Department of Removable Prosthodontics & Gerodontology, Tokyo Dental College, Chiba, Japan; principal investigator, Implant and Tissue Engineering Dental Network-Tokyo, Tokyo, Japan, and assistant professor, Department of Removable Prosthodontics & Gerodontology, Tokyo Dental College, Chiba, Japan.

Published: April 2014

Purpose: The objective of this study was to compare osteoconductivity and biodegradation properties of an in-house fabricated beta-tricalcium phosphate (b-TCP)-collagen composite with those of Bio-Oss Collagen® (Osteohealth, Shirley, NY, USA) using a rat calvarial critical-size defect model.

Materials And Methods: b-TCP-collagen composite material was fabricated by mixing b-TCP granules having a particle size of 0.15 to 0.8 mm and 75% porosity, with bovine dermis-derived soluble collagen sponge. The dry weight ratio of b-TCP granules-to-collagen ratios was 4:1. Bio-Oss Collagen or the b-TCP-collagen composite was used to fill a 5.0 mm-diameter calvarial defect in rats. The defects were evaluated by histological and histomorphological analyses of decalcified histological sections with hematoxylin and eosin staining 6 and 10 weeks, respectively, after surgery.

Results: The defect implanted with the b-TCP composite contained immature bone structures with dense connective tissue in contrast to the abundant fibrous tissue, but no trabecular structure was observed within the defect implanted with Bio-Oss Collagen at 6 weeks postoperatively. Eventually, the defect filled with the b-TCP composite was covered with dense, continuous, mature bone tissue with complete replacement of the graft material. However, in defects filled with Bio-Oss Collagen, only dense connective tissue, containing limited amounts of immature trabecular bone and abundant remnant Bio-Oss particles, was observed. Histomorphological analysis revealed that the b-TCP composite caused greater tissue augmentation with a larger volume of bone tissue observed in the defect and greater bioabsorption of remnant material than Bio-Oss Collagen.

Conclusion: These results indicated that the b-TCP composite has greater osteoconductivity and better biodegradation properties than Bio-Oss Collagen; these properties of the b-TCP-collagen composite complimented bone formation and remodeling.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1708-8208.2012.00467.xDOI Listing

Publication Analysis

Top Keywords

b-tcp-collagen composite
16
bio-oss collagen
16
b-tcp composite
16
composite
9
bone formation
8
bio-oss
8
bio-oss collagen®
8
critical-size defect
8
biodegradation properties
8
defect implanted
8

Similar Publications

Biodegradation property of beta-tricalcium phosphate-collagen composite in accordance with bone formation: a comparative study with Bio-Oss Collagen® in a rat critical-size defect model.

Clin Implant Dent Relat Res

April 2014

President, Implant and Tissue Engineering Dental Network-Tokyo, Tokyo, Japan; associate professor, Implantology and Periodontics, New York University College of Dentistry, NY, USA; professor and chair, Department of Removable Prosthodontics & Gerodontology, Tokyo Dental College, Chiba, Japan; principal investigator, Implant and Tissue Engineering Dental Network-Tokyo, Tokyo, Japan, and assistant professor, Department of Removable Prosthodontics & Gerodontology, Tokyo Dental College, Chiba, Japan.

Purpose: The objective of this study was to compare osteoconductivity and biodegradation properties of an in-house fabricated beta-tricalcium phosphate (b-TCP)-collagen composite with those of Bio-Oss Collagen® (Osteohealth, Shirley, NY, USA) using a rat calvarial critical-size defect model.

Materials And Methods: b-TCP-collagen composite material was fabricated by mixing b-TCP granules having a particle size of 0.15 to 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!