With the help of a silane coupling agent, poly(ethylene glycol) (PEG), a well-biocompatable agent, was grafted onto the surface of ultrahigh molecular weight polyethylene (UHMWPE) by ultraviolet initiation. Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy analysis proved the success of PEG grafting. Water contact angle measurement showed that the modified UHMWPE was obviously improved in surface hydrophilicity and thermogravimetric analysis result showed that its thermostability did not decline even it was pretreated by strong acids. Then, the protein adsorption of the modified UHMWPE was investigated using three model proteins including bovine serum albumin, lysozyme, and fibrinogen. Rabbit blood was used to study the platelet adhesion on the surface of modified UHMWPE. The results indicated that the quantity of protein adsorption on the modified UHMWPE grafted PEG reduced apparently for all the model proteins while there was some specific differences or exceptions among them. It was ascribed to the changed surface chemical composition, surface hydrophilicity and surface topography after modification. The adhesive ability of blood platelets on the modified surface of UHMWPE decreased after PEG grafting. Owing to the improved resistance to fibrinogen adsorption and platelet adhesion, the surface modification might endow the UHWMPE surface better anticoagulation ability according to clotting mechanism.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.a.34301DOI Listing

Publication Analysis

Top Keywords

modified uhmwpe
16
surface
10
surface modification
8
ultrahigh molecular
8
molecular weight
8
weight polyethylene
8
blood platelets
8
peg grafting
8
surface hydrophilicity
8
protein adsorption
8

Similar Publications

The most promising material for uranium extraction from saltwater is generally acknowledged to be fibrous adsorbents. An irradiation-modified anti-biofouling ultra-high-molecular-weight polyethylene (UHMWPE--PGAO) fibrous adsorbent with a hyperbranched structure was synthesized. It exhibited adsorption capacities of 314.

View Article and Find Full Text PDF

Aseptic inflammation and osteolysis triggered by the phagocytosis of implant wear particles by macrophages are important reasons for aseptic loosening (AL) in total joint replacement, which ultimately leads to implant failure. Therefore, the development of implants with long-term effectiveness in preventing AL is a pressing issue. In contrast to the conventional idea of reducing the occurrence of AL through anti-inflammatory treatment, we prepared implants based on a novel concept: to prevent AL by returning the dynamic balance of osteogenesis/osteolysis through dynamic modulation, which is expected to completely resolve the problem of AL.

View Article and Find Full Text PDF

Here, a combination of dopamine self-polymerization and epoxy modified SiO (M-SiO) grafting was proposed, with the purpose of increasing interfacial adhesion of UHMWPE fiber. Inspired by mussel adhesion, polydopamine (PDA) was deposited onto the surface of UHMWPE fiber to form a thin layer with amino and hydroxyl groups. M-SiO nanoparticles were then adhered to fiber surface via chemical reactions by a "two-step" or "one-step" technology.

View Article and Find Full Text PDF

[Comparison of the Quality of the Most Commonly Used New UHMWPE Articulation Inserts of the Total Knee Replacement].

Acta Chir Orthop Traumatol Cech

September 2024

l. ortopedická klinika 1. lékařské fakulty Univerzity Karlovy a Fakultní nemocnice v Motole, Praha.

Purpose Of Study: Total joint replacements (TJR) have become the cornerstone of modern orthopedic surgery. A great majority of TJR employs ultrahigh molecular weight polyethylene (UHMWPE) liners. TJR manufacturers use many different types of UHMWPE, which are modified by various combinations of crosslinking, thermal treatment, sterilization and/or addition of biocompatible stabilizers.

View Article and Find Full Text PDF

The present Bayesian network meta-analysis compared different types of polyethylene liners in total hip arthroplasty (THA) in terms of wear penetration (mm/year) and rate of revision. The type of liners compared were the crosslinked ultra-high molecular weight polyethylene (CPE/UHMWPE), Vitamin E infused highly cross-linked polyethylene (HXLPE-VEPE), modified cross-linked polyethylene (MXLPE), highly cross-linked polyethylene (HXLPE), Cross-linked polyethylene (XLPE). This study was conducted according to the PRISMA extension statement for reporting systematic reviews incorporating network meta-analyses of healthcare interventions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!