Objective: To intraindividually compare a low-tube voltage, low-contrast material dose computed tomography (CT) reconstructed with iterative reconstruction (IR) algorithm at standard tube voltage reconstructed with filtered back projection (FBP) and standard-contrast material dose during liver dynamic CT.

Materials And Methods: Twenty-five patients with liver cirrhosis underwent 64-section multidetector CT. One hundred twenty kilovolt (peak) (kV[p]) with standard contrast material dose of 600 mg of iodine per kilogram (protocol A) and 80 kV(p) with low-contrast material dose of 450 mg of iodine per kilogram (protocol B) CT image sets were reconstructed by using FBP algorithm and that of using IR algorithm with a 60%/40% blend of IR-FBP reconstruction at 80-kV(p) image set (protocol C). Scans obtained during 3 hepatic phases were subjected to quantitative and qualitative analysis.

Results: The mean radiation dose and the contrast medium dose were significantly lower under protocols B and C than under protocol A. In all hepatic phases, all signal-to-noise and contrast-to-noise ratios were greater under protocol C than under other protocols at all anatomic sites. Qualitative analysis showed that image noise and diagnostic acceptability were significantly higher under protocol C.

Conclusion: In all hepatic phases, a low-tube voltage, low-contrast material dose CT with IR algorithm yielded better contrast enhancement and image quality than a standard tube voltage, standard contrast material dose CT with FBP in thin adult patients.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RCT.0b013e31825b821fDOI Listing

Publication Analysis

Top Keywords

material dose
28
low-contrast material
16
tube voltage
16
standard tube
12
hepatic phases
12
dose
10
image quality
8
iterative reconstruction
8
reconstruction algorithm
8
algorithm standard
8

Similar Publications

The presence of N-nitrosamine impurities in pharmaceutical products is well known. In 2019, it resulted in drug recall by the Food and Drug Administration (FDA). Soon, several groups identified the presence of many N-nitrosamines (NAs) in various Active Pharmaceutical Ingredients (APIs) and drug formulations worldwide.

View Article and Find Full Text PDF

The therapeutic window of antibody drug-conjugates (ADC) remains challenging due to safety issues such as interstitial lung disease (ILD) observed with specific deruxtecan-based ADCs. To avoid ILD, we designed M9140 by conjugating the maleimide-containing hydrophilic β-glucuronide linker to exatecan and our anti-CEACAM5 (CarcinoEmbryonic Antigen-related Cell Adhesion Molecule 5) specific antibody. Following repeated iv-infusion at 3 to 30 mg/kg of M9140 every 3 weeks, the pathological findings obtained in cynomolgus monkeys were confined to gastrointestinal and hematolymphoid tissues and resembled the toxicity of exatecan.

View Article and Find Full Text PDF

Background: Inhalation exposure is the gold standard when assessing pulmonary toxicity. However, it typically requires substantial amounts of test material. Intratracheal instillation is an alternative administration technique, where the test substance is suspended in a liquid vehicle and deposited into the lung via the trachea.

View Article and Find Full Text PDF

Impact of diaphragm motion on dosimetry in lower thoracic spine stereotactic body radiotherapy.

Phys Med

January 2025

Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.

Background And Purpose: Free-breathing computed tomography (FBCT) used in treatment planning for lower thoracic (Th8-Th12) spine stereotactic body radiotherapy (SBRT) can cause deviations between planned and irradiated doses due to diaphragm movement (DM). This study analyzed the dosimetric impact of DM on lower thoracic spine SBRT.

Materials And Methods: Data were collected from 19 patients who underwent FBCT and four-dimensional CT (4DCT) during the same session.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to investigate the fundamental properties of spot-scanning proton beams and compare them to Monte Carlo (MC) simulations, both with and without CT calibration, using spatially diverse combinations of materials.

Methods: A heterogeneous phantom was created by spatially distributing titanium, wax, and thermocol to generate six scenarios of heterogeneous combinations. Proton pencil beams ranging in energy from 100 to 226.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!