A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of the distance between Schwalbe's line and the anterior lens capsule as a parameter for the correction of ultrasound biomicroscopic values of the canine iridocorneal angle. | LitMetric

Evaluation of the distance between Schwalbe's line and the anterior lens capsule as a parameter for the correction of ultrasound biomicroscopic values of the canine iridocorneal angle.

Vet Ophthalmol

Laboratory of Advanced Diagnosis and Treatment, Department of Advanced Clinical Medicine, Course of Veterinary Sciences, Graduate School of Life and Environmental Sciences, Osaka Prefecture University, North 1-58, Rinku-orai, Izumisano 598-8531, Japan.

Published: May 2013

Objective: To determine whether the distance between Schwalbe's line (the peripheral termination of Descemet's membrane, i.e., the borderline between the cornea and sclera) and the anterior lens capsule (SLD) is an applicable parameter for correcting raw ultrasound biomicroscopic values of the canine iridocorneal angle (ICA) and to establish a comparative system for the ICA values in different canine breeds with varied body sizes/weights.

Animal Studied: The dogs were divided into four groups based on body weight (BW): <4 kg, 4-8 kg, 8-20 kg, and >20 kg, and 180 normotensive eyes were studied.

Procedures: The ICA microstructure was examined by ultrasound biomicroscopy (UBM) using 40-MHz probes in dogs with or without anesthesia/sedation. Linear regression analysis and correlation coefficients were evaluated between SLD or SLD(2) and UBM measurements; subsequently, noncorrected and SLD-corrected UBM values were statistically assessed.

Results: Significant linear correlations were detected between SLD and the ciliary cleft width, the minimum distance between the angle recess and the scleral venous plexus, and the scleral thickness. Positive linear correlations were also demonstrated between SLD(2) and the ciliary cleft area as well as the scleral venous plexus area. Raw UBM measurements were corrected by using a ratio with SLD on the distance or SLD(2) on the area. Although noncorrected UBM measurements increased with canine BW, SLD-corrected UBM values remained similar with no significant statistical differences in any of the dogs.

Conclusions: Correction with SLD would be clinically useful for comparing UBM measurements of the ICA in dogs with different body sizes/weights.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1463-5224.2012.01043.xDOI Listing

Publication Analysis

Top Keywords

ubm measurements
16
values canine
12
distance schwalbe's
8
anterior lens
8
lens capsule
8
ultrasound biomicroscopic
8
biomicroscopic values
8
canine iridocorneal
8
iridocorneal angle
8
sld-corrected ubm
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!