A case of permanent pacemaker lead endocarditis staphylococcal aureus related is described and management is discussed.
Download full-text PDF |
Source |
---|
J Multidiscip Healthc
January 2025
Nursing Department, Hasan Sadikin General Hospital, Bandung, West Jawa, Indonesia.
Background: Permanent Pacemaker (PPM) implantation is essential in treating cardiac arrhythmias and conduction disorders, especially in patients with heart failure. Although PPM has been proven to improve quality of life and prolong life expectancy in patients with cardiac conduction disorders, post implantation complications still often occur.
Purpose: This study aimed to identify types of complications and associated predictors in patients undergoing PPM implantation.
JACC Case Rep
December 2024
Department of Cardiology, Northern Beaches Hospital, Frenchs Forest, Australia.
A 72-year-old woman underwent left bundle branch area pacing, and subsequent transthoracic echocardiography demonstrated potential septal lead perforation. Transesophageal echocardiography revealed an intracardiac mass, which resolved with anticoagulation. This case highlights left ventricular thrombus as a potential complication of septal lead perforation.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Department of Radiological and Hematological Sciences, Section of Radiology, Università Cattolica del Sacro Cuore, Largo Agostino Gemelli 8 - 00168 Rome, Italy.
Background: Cardiac strangulation (CS) from epicardial pacing leads (EPLs) is a rare and potentially lethal mechanical complication associated with epicardial pacemaker (PM) implantation.
Case Summary: We report a case of a 44-year-old-female patient presenting with chest and left shoulder pain in the absence of reported trauma with history of congenital atrioventricular block treated with epicardial PM implantation during the childhood and subsequent transvenous reimplantation over the years. Troponin I resulted within normal values and ECG, transthoracic echocardiography and chest X-ray documented no acute cardiopulmonary findings.
J Arrhythm
February 2025
Department of Cardiology Nagoya University Graduate School of Medicine Nagoya Japan.
Background: Removal of cardiac implantable electronic devices (CIEDs) is strongly recommended for CIED-related infections, and leadless pacemakers (LPs) are increasingly used for reimplantation. However, the optimal timing and safety of LP implantation after CIED removal for infection remains unclear.This systematic review and meta-analysis aimed to assess complication rates (all-cause mortality and reinfection) when LP implantation was performed simultaneously with or after CIED removal.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
1st Department of Arrhythmia, National Institute of Cardiology, 42 Alpejska Street, 04-628 Warsaw, Poland.
Background: Transvenous lead extraction (TLE) has become an essential component of lead management strategies, but it carries the risk of severe complications, including damage to the tricuspid valve. Currently, there are no established predictors that can help prevent these complications.
Case Summary: An 84-year-old male with a dual-chamber pacemaker was admitted to the hospital due to a pocket fistula resulting from a local infection.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!