Purpose Of The Study: The measurement of stroke volume variation (SVV) using the FloTrac™ system (Edwards Lifescience, USA) is useful to estimate cardiac preload. We evaluated the benefits of SVV monitoring for adjusting fluid supplementation during laparoscopic adrenalectomy under anesthesia in patients with pheochromocytoma.

Subjects And Methods: Among 10 patients who underwent laparoscopic adrenalectomy for pheochromocytoma in our institution from June 2004 to December 2009, SVV was not monitored in 5 patients (group I) and in the other 5 patients (group II), SVV monitoring was performed. Subject age, height and body weight, total volume of fluid supplemented, blood loss, urine output and net fluid in-out balance during the procedure were retrospectively assessed. In those with SVV monitoring, infusion volume was adjusted for SVV less than 13%.

Results: There were significant differences in the patient age and body weight between the two groups (group I: 64.2 years old and 55.1 kg; group II: 43.6 years old and 71.7 kg). Both total infusion volume and urine output were significantly higher in group I compared with group II (5,610 vs. 2,400 ml and 1,125 vs. 750 ml, respectively). Total blood loss was similar between the two groups. Values of the net fluid balance divided by the body weight and total anesthesia period (hr) were significantly lower in group II compared with group I (I; +13.2 in group I and +6.2 in group II, ml/kg/hr).

Conclusions: These data suggest that SVV monitoring is helpful to estimate the optimal volume for fluid supplementation and could prevent excessive fluid infusion during surgical procedures.

Download full-text PDF

Source
http://dx.doi.org/10.5387/fms.58.78DOI Listing

Publication Analysis

Top Keywords

svv monitoring
16
fluid supplementation
12
laparoscopic adrenalectomy
12
body weight
12
group
10
stroke volume
8
volume variation
8
monitoring adjusting
8
adjusting fluid
8
supplementation laparoscopic
8

Similar Publications

Introduction: Dynamic indices of fluid responsiveness (FR) such as pulse pressure variation (PPV) and stroke volume variation (SVV) differ among hemodynamic monitors, which use proprietary algorithms, and vary even over a short period of time. We aimed to compare the baseline values, fluctuation and predictive value for FR of PPV and SVV measured by three minimally invasive monitors.

Patients And Methods: Twenty patients undergoing high-risk abdominal surgery were included and 45 fluid challenges were analysed.

View Article and Find Full Text PDF

Introduction: Patients undergoing cardiovascular surgery may experience hemodynamic instability during the induction of general anesthesia, and anesthetic agents with minimal hemodynamic effects should be administered. Midazolam, a classic benzodiazepine anesthetic, is known to have relatively weak circulatory depression during anesthesia induction compared to other sedatives. On the other hand, remimazolam, a newly approved short-acting benzodiazepine anesthetic, is expected to have fewer circulatory depressant effects.

View Article and Find Full Text PDF

Next-Gen Poly(ε-Caprolactone) Scaffolds: Non-Destructive In Vivo Monitoring and Accelerated Biodegradation.

Adv Healthc Mater

November 2024

Polymer Chemistry and Biomaterials Group, Department of Organic and Macromolecular Chemistry, Centre of Macromolecular Chemistry, Ghent University, Krijgslaan 281, Building S4, Belgie, Ghent, 9000, Belgium.

Poly(ɛ-caprolactone) (PCL) is a biocompatible, biodegradable, and highly mechanically resilient FDA-approved material (for specific biomedical applications, e.g. as drug delivery devices, in sutures, or as an adhesion barrier), rendering it a promising candidate to serve bone tissue engineering.

View Article and Find Full Text PDF
Article Synopsis
  • - The study aimed to evaluate a closed-loop resuscitation algorithm called ReFit1 and ReFit2, which uses various hemodynamic parameters to effectively manage severe hemorrhagic shock in a pig model.
  • - The ReFit algorithm determines the need for fluids and medications based on real-time monitoring of vital signs, such as mean arterial pressure and mixed venous oxygen saturation, to drive automated treatments.
  • - Results showed that the time to stabilize the pigs using these algorithms was comparable to traditional methods used by expert clinicians, with similar treatment volumes, and ReFit1 also successfully addressed complications like acute air embolism in some animals.
View Article and Find Full Text PDF

Background: Our aim was to evaluate the influence of staged goal directed therapy (GDT) on postoperative pulmonary complications (PPCs), intraoperative hemodynamics and oxygenation in patients undergoing Mckeown esophagectomy.

Methods: Patients were randomly divided into three groups, staged GDT group (group A, n = 56): stroke volume variation (SVV) was set at 8-10% during the one lung ventilation (OLV) stage and 8-12% during the two lung ventilation (TLV) stage, GDT group (group B, n = 56): received GDT with a target SVV of 8-12% During the entire surgical procedure, and control group (group C, n = 56): conventional fluid therapy was administered by mean arterial pressure (MAP), central venous pressure (CVP), and urine volume. The primary outcome was the incidence of postoperative pulmonary complications within Postoperative days (POD) 7.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!