Factors affecting continuous beat-to-beat orthostatic blood pressure response in community-dwelling older adults.

Blood Press Monit

The Irish Longitudinal Study on Ageing (TILDA), Chemistry Extension Building, Dublin, Republic of Ireland.

Published: August 2012

Objective: To examine the effect of age, time of day, the timing of medication and food ingestion on orthostatic blood pressure response (OBP) in community-dwelling adults.

Methods: A nationally representative sample of 109 community-dwelling adults aged at least 50 years attended for health assessment in a pilot study of The Irish Longitudinal Study on Ageing. OBP was measured using continuous beat-to-beat plethysmography (Finometer) during active stand, and OBP with excessive artefacts were excluded. Nine outcome variables were supine systolic blood pressure (SBP), lowest standing SBP (nadir), standing SBP at 40, 60 and 120 s and the difference in supine SBP and nadir (delta SBP) and delta at 40, 60 and 120 s. Factors included for multiple linear regression analysis were age, time of assessment, interval from the last meal and whether regular medications were taken on the day. Subgroup analysis was performed on 103 respondents who were not on β-blocker, fludrocortisone and Parkinson medications.

Results: There were 53 men, mean age 62.1 (SD=9.4) years. Older respondents (≥60 years) showed greater delta at 40 s by up to 12.9 mmHg. Delta SBP and delta 40, 60 and 120 were not significantly affected by the time of day or food ingestion. The effect of medications on delta 40 was no longer present in subgroup analysis.

Conclusion: Age was the most significant determinant of OBP and was most strongly associated with greater delta at 40 s. This was independent of the time of day, food and medication ingestion. Continuous beat-to-beat plethysmography provides for a window into the pattern of OBP in community-dwelling adults aged 50 years and older.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MBP.0b013e328356821fDOI Listing

Publication Analysis

Top Keywords

continuous beat-to-beat
12
blood pressure
12
time day
12
orthostatic blood
8
pressure response
8
age time
8
food ingestion
8
obp community-dwelling
8
community-dwelling adults
8
adults aged
8

Similar Publications

We developed a deep learning-based extraction of electrocardiographic (ECG) waves from ballistocardiographic (BCG) signals and explored their use in R-R interval (RRI) estimation. Preprocessed BCG and reference ECG signals were inputted into the bidirectional long short-term memory network to train the model to minimize the loss function of the mean squared error between the predicted ECG (pECG) and genuine ECG signals. Using a dataset acquired with polyvinylidene fluoride and ECG sensors in different recumbent positions from 18 participants, we generated pECG signals from preprocessed BCG signals using the learned model and evaluated the RRI estimation performance by comparing the predicted RRI with the reference RRI obtained from the ECG signal using a leave-one-subject-out cross-validation scheme.

View Article and Find Full Text PDF

There is an ongoing search for a reliable and continuous method of noninvasive blood pressure (BP) tracking. In this study, we investigate the feasibility of utilizing seismocardiogram (SCG) signals, i.e.

View Article and Find Full Text PDF

Assessment of cerebral oxygenation during repeated squat stands following an acute sport-related concussion (SRC) has the potential to identify physiological changes following SRC. All varsity university athletes completed a pre-season assessment and 53 were followed up within 5-days of suffering an SRC. Of the 53 participants, 29 had continuous beat-to-beat blood pressure (BP; sampled at 200 hz) collected by finger photoplethysmography, and 53 had right prefrontal cortex oxygenation collected by near-infrared spectroscopy (NIRS; sampled at 10 hz).

View Article and Find Full Text PDF

Novel Insights Continuous intrapartum fetal heart rate assessment by fetal scalp electrode may record arrythmias like recurrent atrial ectopic beats and depict an increased fetal heart rate variability mimicking a ZigZag pattern. Introduction Fetal scalp electrode (FSE) is considered the gold standard for the intrapartum monitoring of the fetal heart rate (FHR) being associated with the lowest rate of signal loss and artifacts including the recording of the maternal heart rate. FSE acquires a fetal electrocardiogram and evaluates the time intervals between successive R waves.

View Article and Find Full Text PDF

Preoperative autonomic failure in neonates with critical congenital heart disease.

Early Hum Dev

January 2025

The Zickler Family Prenatal Pediatrics Institute, Children's National Hospital, Washington, DC, USA; The Developing Brain Institute, Children's National Hospital, Washington, DC, USA; Department of Pediatrics, The George Washington University School of Medicine, Washington, DC, USA. Electronic address:

Background: Neonates with critical congenital heart disease (cCHD) undergo a complicated transition to ex-utero life. However, continuous monitoring of autonomic tone using heart rate variability is currently lacking.

Materials And Methods: We retrieved continuous electrocardiograms from the time of admission or from 10 days prior to surgery for neonates with dextro-transposition of the great arteries (d-TGA) and hypoplastic left heart syndrome (HLHS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!