Simulation of ultrasound images based on computed tomography (CT) data has previously been performed with different approaches. Shadow effects are normally pronounced in ultrasound images, so they should be included in the simulation. In this study, a method to capture the shadow effects has been developed, which makes the simulated ultrasound images appear more realistic. The method using a focused beam tracing model gives diffuse shadows that are similar to the ones observed in measurements on real objects. Ultrasound images of a cod (Gadus morhua) were obtained with a BK Medical 2202 ProFocus ultrasound scanner (BK Medical, Herlev, Denmark) equipped with a dedicated research interface giving access to beamformed radio frequency data. CT images were obtained with an Aquilion ONE Toshiba CT scanner (Toshiba Medical Systems Corp., Tochigi, Japan). CT data were mapped from Hounsfield units to backscatter strength, attenuation coefficients, and characteristic acoustic impedance. The focused beam tracing model was used to create maps of the transmission coefficient and scattering strength maps. Field II was then used to simulate an ultrasound image of 38.9 × 55.3 × 4.5 mm, using 10(6) point scatterers. As there is no quantitative method to assess quality of a simulated ultrasound image compared to a measured one, visual inspection was used for evaluation.

Download full-text PDF

Source
http://dx.doi.org/10.1121/1.4726031DOI Listing

Publication Analysis

Top Keywords

ultrasound images
20
shadow effects
12
simulated ultrasound
12
focused beam
12
beam tracing
12
tracing model
12
ultrasound
8
computed tomography
8
ultrasound image
8
images
7

Similar Publications

Importance: Disease characteristics of genetically mediated coronary artery disease (CAD) on coronary angiography and the association of genomic risk with outcomes after coronary angiography are not well understood.

Objective: To assess the angiographic characteristics and risk of post-coronary angiography outcomes of patients with genomic drivers of CAD: familial hypercholesterolemia (FH), high polygenic risk score (PRS), and clonal hematopoiesis of indeterminate potential (CHIP).

Design, Setting, And Participants: A retrospective cohort study of 3518 Mass General Brigham Biobank participants with genomic information who underwent coronary angiography was conducted between July 18, 2000, and August 1, 2023.

View Article and Find Full Text PDF

Perfusion Capacity as a Predictive Index for Assessing Visual Functional Recovery in Patients With Idiopathic Epiretinal Membrane.

Transl Vis Sci Technol

January 2025

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China.

Purpose: This study investigates the association between visual function and retinal vasculature metrics, particularly perfusion capacity (PC), in eyes with idiopathic epiretinal membrane (iERM), using optical coherence tomography angiography (OCTA).

Methods: This retrospective study includes 30 eyes from 30 iERM patients who had surgery, with a three-month follow-up period. In addition, 28 eyes from 28 healthy individuals served as a control group.

View Article and Find Full Text PDF

Novel Meningoencephalomyelitis Associated With Vimentin IgG Autoantibodies.

JAMA Neurol

January 2025

Department of Neurology, Xuanwu Hospital Capital Medical University, National Center for Neurological Disorders, Beijing, China.

Importance: Autoantibodies targeting astrocytes, such as those against glial fibrillary acidic protein (GFAP) or aquaporin protein 4, are crucial diagnostic markers for autoimmune astrocytopathy among central nervous system (CNS) autoimmune disorders. However, diagnosis remains challenging for patients lacking specific autoantibodies.

Objective: To characterize a syndrome of unknown meningoencephalomyelitis associated with an astrocytic autoantibody.

View Article and Find Full Text PDF

Ultrasound-guided minimally invasive thread release of carpal tunnel: a cadaveric study.

Radiol Med

January 2025

Neuromuscular Imaging Ordinationszentrum Döbling, Heiligenstädter Straße 46-48, 1190, Vienna, Austria.

Purpose: Thread release of the carpal tunnel is the most recent of several minimally invasive ultrasound-guided carpal tunnel release techniques. The purpose of this article is to provide a step-by-step guide for minimally invasive, ultrasound-guided thread release of the carpal tunnel focused on transecting the transverse carpal ligament with minimal damage to the palmar aponeurosis on anatomical specimens.

Methods: Fifteen ultrasound-guided carpal tunnel thread releases were performed on the wrists of soft-embalmed anatomical specimens, which were dissected immediately after the intervention.

View Article and Find Full Text PDF

Diagnostic Value of Serum miR-499a-5p in Chinese Children with Autism Spectrum Disorders.

J Mol Neurosci

January 2025

Department II of Acupuncture and Moxibustion, Dongzhimen Hospital Beijing University of Chinese Medicine, No. 116, Cuiping West Road, Tongzhou District, Beijing, 101121, China.

The purpose of this study was to investigate the expression of miR-499a-5p in children with autism spectrum disorders (ASD) and its value in early diagnosis of ASD. This is a retrospective case-control study that included 40 children with ASD as a case group and 43 healthy children as a control group. Magnetic resonance imaging (MRI) was performed on all subjects, and the children were scored with childhood autism rating scale (CARS) and autism behavior checklist (ABC).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!