Accuracy and validity of stitching sectional cone beam computed tomographic images.

J Craniofac Surg

Department of Oral and Maxillofacial Surgery, National Health Insurance Corporation Ilsan Hospital, Goyang, Gyeonggi-do, Republic of Korea.

Published: July 2012

AI Article Synopsis

  • The study examined the accuracy of three-dimensional images of skulls created by stitching together CBCT images compared to single MDCT images.
  • Using an optical three-dimensional scanner, MDCT, and CBCT, positional errors were assessed between the different imaging methods.
  • Results showed that manually merged CBCT images were as accurate as MDCT images, while software-aligned CBCT images had significant positional differences from the MDCT images.

Article Abstract

To determine whether three-dimensionally reconstructed images of skulls created by stitching multiple cone beam computed tomographic (CBCT) images are as accurate as single images obtained using multidetector computed tomography (MDCT), 10 skull models were scanned using an optical three-dimensional scanner, MDCT, and CBCT. Cone beam CT images at 3 different levels of the skull were manually superimposed and stitched. The reconstructed CBCT images at each level were aligned and fused using computer software and then compared to the nominal reference image obtained from the optical three-dimensional scanner by determining positional errors. The reconstructed MDCT images were also compared, and the differences in the mean errors for the 3 image types compared with the nominal reference image data were evaluated. There were no significant differences between the MDCT images and the manually merged CBCT images (Wilcoxon signed rank test, P = 0.017). In contrast, there were significant differences between the MDCT images and the software-aligned CBCT images (P = 0.005). Manual stitching of CBCT sectional images at different levels can provide accurate anatomic details of the oral and maxillofacial regions.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SCS.0b013e31824e2c85DOI Listing

Publication Analysis

Top Keywords

cbct images
16
cone beam
12
images
12
mdct images
12
beam computed
8
computed tomographic
8
optical three-dimensional
8
three-dimensional scanner
8
images levels
8
compared nominal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!