Stuttering is generally considered to be a speech disorder that affects ∼1% of the global population. Various forms of speech feedback have been shown to reduce overt stuttered speaking, and in particular, second speech signal through speech feedback has drastically reduced utterances of stuttered speech in adults with persistent stuttering. This study reports data for increased overt fluency of speech in an adult stuttering population, whereby the vocalization of the speaker is captured by a microphone or an accelerometer, signal processed, and returned as mechanical tactile speech feedback to the speaker's skin. A repeated measures analysis of variance was used to show that both the microphone and the accelerometer speaking conditions were significantly more fluent than a control (no feedback) condition, with the microphone-driven tactile feedback reducing instances of stuttering by 71% and the accelerometer-driven tactile feedback reducing instances of stuttering by 80%. It is apparent that self-generated tactile feedback can be used to enhance fluency significantly in those who stutter.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/WNR.0b013e328356b108 | DOI Listing |
Sci Rep
December 2024
Department of Urology, The Jikei University School of Medicine, Kashiwa Hospital, Kashiwashita 163-1, Kashiwa, Chiba, 277-8567, Japan.
To evaluate the safety and efficacy of the Saroa Surgical Robot System in robot-assisted laparoscopic radical prostatectomy (RARP). We enrolled 60 patients who underwent RARP using either the Saroa (n = 9) or da Vinci Xi (n = 51) systems at Jikei University Kashiwa Hospital from January 2022 to March 2024. We compared preoperative characteristics, perioperative outcomes, complications, and postoperative urinary continence at three months between the two groups.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Health Science and Technology, Aalborg University, Aalborg, Denmark.
EMG feedback improves force control of a myoelectric hand prosthesis by conveying the magnitude of the myoelectric signal back to the users via tactile stimulation. The present study aimed to test if this method can be used by a participant with a high-level amputation, and whose muscle used for prosthesis control (pectoralis major) was not intuitively related to hand function. Vibrotactile feedback was delivered to the participant's torso, while the control was tested using EMG from three different muscles.
View Article and Find Full Text PDFFront Sports Act Living
December 2024
Research Institute for Sport and Exercise, University of Canberra, Canberra, ACT, Australia.
Previous research has demonstrated that postural stability may be improved by increasing stimulation to the somatosensory system. Wearing lower limb compression garments or textured in-soles have been found to be effective short-term methods for improving postural stability, hypothesized to be due to enhanced tactile feedback. The aim of this study was to assess whether a combined compression-tactile sock increases postural stability in healthy adults, compared to barefoot.
View Article and Find Full Text PDFBiomimetics (Basel)
December 2024
School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China.
This study develops biomimetic strategies for slip prevention in prosthetic hand grasps. The biomimetic system is driven by a novel slip sensor, followed by slip perception and preventive control. Here, we show that biologically inspired sensorimotor pathways can be restored between the prosthetic hand and users.
View Article and Find Full Text PDFFront Neurosci
December 2024
Research and Exploratory Development Department, Johns Hopkins University Applied Physics Laboratory, Laurel, MD, United States.
Objective: Targeted transcutaneous electrical nerve stimulation (tTENS) is a non-invasive neural stimulation technique that involves activating sensory nerve fibers to elicit tactile sensations in a distal, or referred, location. Though tTENS is a promising approach for delivering haptic feedback in virtual reality or for use by those with somatosensory deficits, it was not known how the perception of tTENS might be influenced by changing wrist position during sensorimotor tasks.
Approach: We worked with 12 able-bodied individuals and delivered tTENS by placing electrodes on the wrist, thus targeting the ulnar, median, and radial nerves, and eliciting tactile sensations in the hand.