In this study, a new gas chromatography-mass spectrometry (GC-MS) method, using the very selective negative chemical ionization (NCI) mode, was developed and applied in combination with a modified acetonitrile-based extraction method (QuEChERS) for the analysis of a large number of pesticide residues (51 pesticides, including isomers and degradation products) in green coffee beans. A previously developed integrated sample homogenization and extraction method for both pesticides and mycotoxins analysis was used. An homogeneous slurry of green milled coffee beans and water (ratio 1:4, w/w) was prepared and extracted with acetonitrile/acetic acid (1%), followed by magnesium sulfate addition for phase separation. Aliquots from this extract could be used directly for LC-MS/MS analysis of mycotoxins and LC-amenable pesticides. For GC-MS analysis, a further clean-up was necessary. C18- and PSA-bonded silica were tested as dispersive solid-phase extraction (d-SPE) sorbents, separate and as a mixture, and the best results were obtained using C18-bonded silica. For the optimal sensitivity and selectivity, GC-MS detection in the NCI-selected ion monitoring (SIM) mode had to be used to allow the fast analysis of the difficult coffee bean matrix. The validation was performed by analyzing recovery samples at three different spike concentrations, 10, 20 and 50 μg kg(-1), with 6 replicates (n=6) at each concentration. Linearity (r(2)) of calibration curves, estimated instrument and method limits of detection and limits of quantification (LOD(i), LOD(m), LOQ(i) and LOQ(m), respectively), accuracy (as recovery %), precision (as RSD%) and matrix effects (%) were determined for each individual pesticide. From the 51 analytes (42 parent pesticides, 4 isomers and 5 degradation products) determined by GC-MS (NCI-SIM), approximately 76% showed average recoveries between 70-120% and 75% and RSD ≤ 20% at the lowest spike concentration of 10 μg kg(-1), the target method LOQ. For the spike concentrations of 20 and 50 μg kg(-1), the recoveries and RSDs were even better. The validated LOQ(m) was 10, 20 and 50 μg kg(-1) for respectively 33, 3 and 6 of the analytes studied. For five compounds, the European Union method performance requirements for the validation of a quantitative method (average recoveries between 70-120% and repeatability RSD ≤ 20%) were not achieved and 4 problematic pesticides (captan, captafol, folpet and dicofol) could not be detected as their parent compound, but only via their degradation products. Although the matrix effect (matrix-enhanced detector response) was high for all pesticides studied, the matrix interference was minimal, due to the high selectivity obtained with the GC-NCI-MS detection. Matrix-matched calibration for applying the method in routine analysis is recommended for reliable quantitative results.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2012.06.041 | DOI Listing |
Acta Neurochir Suppl
October 2019
Department of Neurosurgery, The Third Xiangya Hospital, Central South University, Changsha, China.
Background: Subarachnoid hemorrhage (SAH) is a severe and emergent cerebrovascular disease, the prognosis of which usually very poor. Microthrombi formation highlighted with inflammation occurs early after SAH. As the main cause of DCI, microthrombosis associated with the prognosis of SAH.
View Article and Find Full Text PDFMacromol Biosci
January 2017
Pharmaceutical Sciences Division, School of Pharmacy, University of Wisconsin, 777 Highland Avenue, Madison, WI, 53705, USA.
Triolimus is a multi-drug loaded polymeric micelle containing paclitaxel (PTX), 17-allylamino-17-demethoxygeldanamycin (17-AAG), and rapamycin (RAP). This study examines the radiosensitizing effect of Triolimus in vitro and in vivo. Radiosensitizing effects of Triolimus on A549 cells are dose dependent and at 2 × 10 m, Triolimus shows significant radiosensitization even at low radiation doses (2 Gy).
View Article and Find Full Text PDFXenobiotica
March 2017
a Epizyme Inc , Cambridge , MA , USA and.
1. The plasma clearance of the first-in-class DOT1L inhibitor, EPZ-5676 (pinometostat), was shown to be markedly lower in human compared to the preclinical species, mouse, rat and dog. 2.
View Article and Find Full Text PDFAims: The primary aim of this study was to describe the pharmacokinetics of total and unbound bupivacaine and ropivacaine following epidural bolus and infusion in neonates and young infants. Secondary aims were to investigate the influence of alpha-1-acid glycoprotein (AAG) on the concentration-time profiles and to determine the efficacy and adverse event profile of the epidural regimen.
Methods/materials: Thirty-one infants aged 40-63 weeks of postmenstrual age (PMA) undergoing hernia repair or abdominal surgery received an epidural injection of 1.
Paediatr Anaesth
September 2004
Department of Anaesthesiology, Universitätsklinikum Mannheim, Mannheim, Germany.
Background: The aims of this study were to evaluate pharmacokinetics, efficacy and safety of ropivacaine in infants aged 0-12 months following a single caudal injection.
Methods: Term ASA I-III patients, scheduled for surgery, with a body weight of > or = 2500 g received a caudal block with ropivacaine 2 mg x ml(-1), 1.0 ml x kg(-1).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!