[Sauer's binaural number test in noise. Significance in expertise].

HNO

Klinik und Poliklinik für Hals-Nasen-Ohrenheilkunde, Ludwig-Maximilians-Universität, Marchioninistr. 15, 81377, München, Deutschland.

Published: October 2012

Objective: For the determination of speech intelligibility in the expertise of hearing loss, the Freiburg speech test (number test and monosyllable test) is recommended in the Federal Republic of Germany. In the former German Democratic Republic, Sauer's binaural number test with 70 dB background noise ("beidohriger Zahlentest", BZT) was a standard element in expert opinions and was used in the calculation of bodily injury ("Körperschaden"). In the current practice, a hearing test in noise is still lacking. The present study analyzes whether and to what degree the impairment ("Grad der Schädigungsfolgen", GdS) changes when also considering Sauer's test.

Material And Methods: In a collective of 78 patients with hearing loss (66 patients with high-frequency hearing loss and 12 patients with pancochlear hearing loss) and 22 normal hearing controls, the following audiometric measurements were conducted: pure tone audiometry, speech audiometry (Freiburg speech test), free field audiometry with and without noise, and Sauer's test. Subsequently, the hearing loss for both sides was calculated taking into consideration the values obtained with and without Sauer's test, and the respective GdS was determined.

Results: Patients with high-frequency hearing loss and pancochlear hearing loss had a trend for higher GdS (approximately 2 and 5%, respectively), compared to the established algorithm without the use of hearing tests in noise. However, neither the Mann-Whitney U-test nor the Bland-Altman analysis yielded relevant differences between the two methods to calculate the GdS.

Conclusion: The routine implementation of Sauer's test in the expertise of hearing loss cannot be recommended, since no relevant change in the GdS can be expected. This is especially true for high-frequency hearing loss. In pancochlear hearing loss, use of Sauer's test can be considered if problems concerning hearing in situations with background noise are present-at least until more advanced hearing tests optimized for use in noise have been integrated into the tables for GdS calculation.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00106-012-2544-8DOI Listing

Publication Analysis

Top Keywords

hearing loss
40
sauer's test
16
hearing
15
number test
12
high-frequency hearing
12
pancochlear hearing
12
test
11
loss
10
binaural number
8
test noise
8

Similar Publications

Objective: Evaluate inpatient audiometry on clinical decision-making. Assess stakeholder perspectives on the practice of inpatient audiometry and financial impact.

Study Design: This is a mixed methods study utilizing retrospective chart review, a focus group, and financial analyses.

View Article and Find Full Text PDF

The Association Between Hearing Loss and Depression in a Large Electronic Health Record System.

Otolaryngol Head Neck Surg

January 2025

Department of Otolaryngology-Head and Neck Surgery, Columbia University Vagelos College of Physicians and Surgeons,  NewYork-Presbyterian/Columbia University Irving Medical Center, New York, New York, USA.

Objective: Hearing loss (HL) is associated with depression, but existing datasets are limited by the type of data available for both hearing and mental health conditions. The purpose of this study is to determine if there is an association between HL and depressive disorders within a large bi-institutional electronic health record (EHR) system containing more granular diagnostic information.

Study Design: Cross-sectional epidemiologic study.

View Article and Find Full Text PDF

Noise-induced hearing loss (NIHL) is a common occupational condition. The aim of this study was to develop a classification model for NIHL on the basis of both functional magnetic resonance imaging (fMRI) and structural magnetic resonance imaging (sMRI) by applying machine learning methods. fMRI indices such as the amplitude of low-frequency fluctuation (ALFF), fractional amplitude of low-frequency fluctuation (fALFF), regional homogeneity (ReHo), degree of centrality (DC), and sMRI indices such as gray matter volume (GMV), white matter volume (WMV), and cortical thickness were extracted from each brain region.

View Article and Find Full Text PDF

[Clinical characteristics and prognosis of type 1 infratentorial superficial siderosis].

Zhonghua Yi Xue Za Zhi

February 2025

Department of Neurology, Huashan Hospital, Fudan University, Shanghai 200040, China.

A total of 7 patients with type 1 infratentorial superficial siderosis(iSS-1)in Memory Clinic at Huashan Hospital, Fudan University from March 2019 to March 2023 were respectively collected to analyze the clinical characteristics and treatment, and followed up for 12 months. There were 7 patients, 2 males and 5 females, aged 56 (49-60) years. The 4 patients who underwent cognitive assessment had varying degree of cognitive impairment, with 2 patients exhibiting severe executive function impairment.

View Article and Find Full Text PDF

The primary concern among adults with regard to their hearing is the difficulty in comprehending speech, particularly in noisy environments. The constant need to listen attentively leads to heightened frustration, fatigue and decreased concentration. According to research, high-frequency hearing loss could have negative implications on speech perception and make it even harder to communicate.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!