In static intensity-modulated radiation therapy (IMRT), the fundamental factors that determine the quality of a plan are the number of beams and their angles. The objective of this study is to investigate the effect of beam angle optimization (BAO) on the beam number in IMRT. We used six head and neck cases to carry out the study. Basically the methodology uses a parameter called "Beam Intensity Profile Perturbation Score" (BIPPS) to determine the suitable beam angles in IMRT. We used two set of plans in which one set contains plans with equispaced beam configuration starting from beam numbers 3 to 18, and another set contains plans with optimal beam angles chosen using the in-house BAO algorithm. We used quadratic dose-based single criteria objective function as a measure of the quality of a plan. The objective function scores obtained for equispaced beam plans and optimal beam angle plans for six head and neck cases were plotted against the beam numbers in a single graphical plot for effective comparison. It is observed that the optimization of beam angles reduces the beam numbers required to produce clini-cally acceptable dose distribution in IMRT of head and neck tumors. Especially N0.1 (represents the beam number at which the objective function reaches a value of 0.1) is considerably reduced by beam angle optimization in almost all the cases included in the study. We believe that the experimental findings of this study will be helpful in understanding the interplay between beam angle optimization and beam number selection process in IMRT which, in turn, can be used to improve the performance of BAO algorithms and beam number selection process in IMRT.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5716515PMC
http://dx.doi.org/10.1120/jacmp.v13i4.3912DOI Listing

Publication Analysis

Top Keywords

beam angle
20
beam
18
angle optimization
16
beam numbers
16
head neck
16
beam number
16
imrt head
12
beam angles
12
set plans
12
objective function
12

Similar Publications

Background: Immature maxillary central teeth can be managed by using several treatment options. The aim of this finite element stress analysis study was to evaluate the effect of different treatment procedures on the stresses on immature maxillary incisor teeth models that generated on cone beam computed tomography, by trauma and bite forces.

Methods: A total of 11 different models consisting of revascularization treatment using MTA and biodentine and the state of the root apex formed with cement after treatment, apexification, modified apexification, traditional root canal treatment and two different control groups have been created.

View Article and Find Full Text PDF

Trabecular meshwork ultrastructural changes in primary and secondary glaucoma.

Sci Rep

January 2025

Ophthalmic Pathology Laboratory, L V Prasad Eye Institute, Kallam Anji Reddy Campus, 500034, Hyderabad, India.

To examine ultrastructural changes in the trabecular meshwork (TM) in patients with primary and secondary glaucoma using scanning electron microscopy (SEM). This was a qualitative descriptive hospital-based study on the ultrastructure of the TM. Pure TM samples were collected after microincisional trabeculectomy from 26 patients with primary or secondary glaucoma and 10 control samples from eye bank donor corneas.

View Article and Find Full Text PDF

Real-time cone-beam computed tomography (CBCT) provides instantaneous visualization of patient anatomy for image guidance, motion tracking, and online treatment adaptation in radiotherapy. While many real-time imaging and motion tracking methods leveraged patient-specific prior information to alleviate under-sampling challenges and meet the temporal constraint (< 500 ms), the prior information can be outdated and introduce biases, thus compromising the imaging and motion tracking accuracy. To address this challenge, we developed a framework (DREME) for real-time CBCT imaging and motion estimation, without relying on patient-specific prior knowledge.

View Article and Find Full Text PDF

Background: The collum angle, tooth dimensions, root length, and alveolar bone thickness have a significant impact on orthodontic diagnosis and treatment planning. The boundaries of orthodontic tooth movement are determined by alveolar bone thickness and dimensions while the collum angle determines the appropriate positioning of the root relative to the cortical plate. This study aimed to compare the collum angle, crown dimensions, root length, and alveolar bone thickness of the upper and lower incisors, canines, and premolars in subjects with varying anteroposterior relationships.

View Article and Find Full Text PDF

This study presents a generalized design strategy for novel terahertz-wave polarization space-division multiplexing meta-devices, functioning as multi-polarization generators, modulators, and analyzers. It introduces the spin-decoupled phase control method by combining gradient phase design with circular polarization multiplexing techniques, enabling exceptional flexibility in controlling the polarization directions and spatial distributions of multiple output beams. The meta-device M-4D is significantly demonstrated as proof of concept, which converts an incident linearly polarized wave into four beams with distinct polarization angles.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!