Patient-specific computational fluid dynamics (CFD) is a powerful tool for researching the role of blood flow in disease processes. Modern clinical imaging technology such as MRI and CT can provide high resolution information about vessel geometry, but in many situations, patient-specific inlet velocity information is not available. In these situations, a simplified velocity profile must be selected. We studied how idealized inlet velocity profiles (blunt, parabolic, and Womersley flow) affect patient-specific CFD results when compared to simulations employing a "reference standard" of the patient's own measured velocity profile in the carotid bifurcation. To place the magnitude of these effects in context, we also investigated the effect of geometry and the use of subject-specific flow waveform on the CFD results. We quantified these differences by examining the pointwise percent error of the mean wall shear stress (WSS) and the oscillatory shear index (OSI) and by computing the intra-class correlation coefficient (ICC) between axial profiles of the mean WSS and OSI in the internal carotid artery bulb. The parabolic inlet velocity profile produced the most similar mean WSS and OSI to simulations employing the real patient-specific inlet velocity profile. However, anatomic variation in vessel geometry and the use of a nonpatient-specific flow waveform both affected the WSS and OSI results more than did the choice of inlet velocity profile. Although careful selection of boundary conditions is essential for all CFD analysis, accurate patient-specific geometry reconstruction and measurement of vessel flow rate waveform are more important than the choice of velocity profile. A parabolic velocity profile provided results most similar to the patient-specific velocity profile.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3625536PMC
http://dx.doi.org/10.1115/1.4006681DOI Listing

Publication Analysis

Top Keywords

velocity profile
32
inlet velocity
24
wss osi
12
velocity
10
velocity profiles
8
patient-specific computational
8
computational fluid
8
fluid dynamics
8
carotid bifurcation
8
vessel geometry
8

Similar Publications

There is scant information available about the blood flow of the pulmonary artery in avian cardiology. In human medicine, the shape of the Doppler sonographic blood flow profile of the pulmonary artery can be used to access the pressure conditions of the right heart. With this background, this study focused on the examination of the acceleration and deceleration phase of the pulsed-wave Doppler flow profile of the pulmonary artery of healthy racing pigeons.

View Article and Find Full Text PDF

The Silway River has historically failed to meet safe fecal coliform levels due to improper waste disposal. The river mouth is located in General Santos City, the tuna capital of the Philippines and a leading producer of hogs, cattle, and poultry. The buildup of contaminants due to direct discharge of waste from chicken farms and existing water quality conditions has led to higher fecal matter in the Silway River.

View Article and Find Full Text PDF

Methylcellulose enhances resolution in gravitational field-flow fractionation: Going beyond viscosity.

J Chromatogr A

December 2024

Department "Area Materno-Infantile" Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan Italy.

Gravitational Field-Flow Fractionation (GrFFF) is an elution-based method designed for the separation of particles ranging from a few micrometers up to approximately 100 μm in diameter. Separation occurs over time, with particles being fractionated based on size and other physico-chemical properties. GrFFF takes advantage of gravitational forces acting perpendicularly to a laminar flow in a thin channel.

View Article and Find Full Text PDF

This Letter describes the first, to the best of our knowledge, demonstration of a velocity measurement by nitric oxide ionization induced flow tagging and imaging (NiiFTI) of a high-enthalpy hypersonic flow utilizing naturally formed nitric oxide. The measurements were conducted in the hypervelocity expansion tunnel (HXT) at Texas A&M University in Mach 8.5 and Mach 10 flows near an ogive test article.

View Article and Find Full Text PDF

Long-term egg-protein hydrolysate consumption improves endothelial function: a randomized, double-blind, placebo-controlled trial in older adults with overweight or obesity.

Eur J Nutr

December 2024

Department of Nutrition and Movement Sciences, NUTRIM Research Institute of Nutrition and Translational Research in Metabolism, Maastricht University Medical Center+, Universiteitssingel 50, PO Box 616, 6200 MD, Maastricht, The Netherlands.

Purpose: The dietary egg-protein hydrolysate Newtricious (NWT)-03 has previously demonstrated improvements in blood pressure and metabolic profiles. However, the long-term effects on vascular function and cardiometabolic risk markers are unknown.

Methods: Forty-four older (aged 60-75) adults with overweight/obesity experiencing elevated Subjective Cognitive Failures (SCF) were randomized into a 36-week, double-blind, placebo-controlled trial.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!