The largely adopted reversed-phase HPLC analysis of the molecular species of isothiocyanates (ITCs) was performed and showed losses during the chromatographic run with eight ITCs. These losses, which obviously impact the accuracy of quantitative determinations, were due to precipitation in the chromatographic system. At 22°C, they ranged from 5.4% for sulforaphane (SFN) to 11.0% for benzyl-ITC when ITCs were injected at 80 μg mL(-1) , but they were up to three times higher at 1 mg mL(-1) reaching 31.9% for benzyl-ITC. The water solubility of the ITCs was a key determinant of the extent of the measured loss. When the column was heated at 60°C, losses in injected ITCs were reduced, in comparison with 22, 40, and 50°C, by two to ten times depending on the ITC considered. A reversed-phase HPLC method based on column heating was suggested and its quantitative performance was determined. It was then applied to the separation of methylene chloride extracts of various cruciferous vegetables. Ally-ITC, SFN, and iberin in cabbage; SFN and iberin in cauliflower; and allyl-ITC and phenylethyl-ITC in horseradish could be identified and quantified. The obtained results cast doubt on quantitative determinations of ITCs that are carried out at room temperature using reversed-phase HPLC.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jssc.201200071 | DOI Listing |
Rapid Commun Mass Spectrom
May 2025
Technology Center of Qingdao Customs, Qingdao, China.
The presence of pesticide residues in textiles poses a risk to human health. We established a robust and high-throughput liquid chromatography-tandem mass spectrometry method for the determination of 115 pesticide residues in textiles. In this study, we evaluated high-performance liquid chromatography-tandem mass spectrometry conditions and sample extraction methods, including separation performance of different columns, mass conditions, extraction solvent, and extraction time.
View Article and Find Full Text PDFBiotechnol Prog
January 2025
Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University, Okayama, Japan.
The production of disulfide-containing recombinant proteins often requires refolding of inclusion bodies before purification. A pre-refolding purification step is crucial for effective refolding because impurities in the inclusion bodies interfere with refolding and subsequent purification. This study presents a new pre-refolding procedure using a reversible S-cationization technique for protein solubilization and purification by reversed-phase high performance liquid chromatography.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
January 2025
Université Clermont Auvergne, Institut Universitaire de Technologie, UMR INSERM-UCA, U1240, Imagerie Moléculaire et Stratégies Théranostiques (IMoST), 5 Avenue Blaise Pascal, 63000 Clermont-Ferrand, France.
A method using high-performance liquid chromatography coupled with fluorescence detection (HPLC-FLD) was developed and validated to quantify the innovative tool LightSpot®-FL-1, a selective permeability-glycoprotein (P-gp)-targeted fluorescent conjugate used to measure P-gp expression in cell samples. Quantifying P-gp is a major challenge in oncology as its overexpression in many cancer cells results in Multidrug Resistance (MDR) associated with chemotherapy failure. To develop the method reported herein, both sample preparation and analysis parameters were investigated.
View Article and Find Full Text PDFJ Am Soc Mass Spectrom
January 2025
MTA-ELTE Lendület (Momentum) Ion Mobility Mass Spectrometry Research Group, ELTE Eötvös Loránd University, Institute of Chemistry, Department of Analytical Chemistry, Pázmány Péter sétány 1/A, H-1117 Budapest, Hungary.
Cyclic ion mobility-mass spectrometry (cIM-MS) is a powerful technique for separating and identifying isomeric mixtures of compounds. When coupled with chromatography, cIM-MS creates a multidimensional separation system, with high resolving power and peak capacity. In this study, we report the cyclic ion mobility separation and high-resolution mass spectrometry identification of four regioisomers of a Sugammadex-related impurity, abbreviated as Di-OH-SGM.
View Article and Find Full Text PDFTrop Med Infect Dis
December 2024
Med Biotech Laboratories, Kampala P.O. Box 9364, Uganda.
Indoor residual spraying (IRS) and the use of insecticide-treated bednets for malaria vector control have contributed substantially to a reduction in malaria disease burden. However, these control tools have important shortcomings including being donor-dependent, expensive, and often failing because of insufficient uptake. We assessed the safety and efficacy of a user-friendly, locally tailored malaria vector control approach dubbed "Hut Decoration for Malaria Control" (HD4MC) based on the incorporation of a WHO-approved insecticide, Actellic 300 CS, into a customary hut decoration practice in rural Uganda where millions of the most vulnerable and malaria-prone populations live in mud-walled huts.