Is portable monitoring for diagnosing obstructive sleep apnea syndrome suitable in elderly population?

Sleep Breath

Disciplina de Medicina e Biologia do Sono, Departamento de Psicobiologia, Universidade Federal de São Paulo-UNIFESP, Rua Napoleao de Barros, 925, 04024-002 São Paulo, Brazil.

Published: May 2013

AI Article Synopsis

  • Obstructive sleep apnea syndrome (OSAS) is common in older adults, and at-home portable monitoring (PM) may serve as a viable alternative to the standard sleep study known as polysomnography (PSG) for diagnosing this condition.
  • * The study involved patients over 65 with suspected OSAS who underwent two types of evaluations: at-home PM and simultaneous PM with PSG, allowing comparisons of the apnea-hypopnea index (AHI) from each method.
  • * Results showed that PM accurately diagnosed OSAS in elderly patients, with strong correlations between the different AHI values, indicating that PM can be effectively used instead of PSG for high-risk older adults.*

Article Abstract

Purpose: Obstructive sleep apnea syndrome (OSAS) is highly prevalent in the elderly. Unattended, at-home portable monitoring (PM) is a diagnostic alternative to polysomnography in adults with high clinical probability of OSAS. However, no studies have evaluated the diagnostic accuracy of PM in elderly population. The aim of our study was to evaluate the effectiveness of PM in elderly patients.

Methods: We selected patients aged over 65 years with suspected OSAS. Two-order randomized evaluations were performed: one night of at-home PM (PMhome) and one night of simultaneous PM and polysomnography (PSG) in the sleep lab (PSG+PM). We obtained three different apnea-hypopnea index (AHI): AHI from PSG (AHI PSG), AHI from at-home PM (AHI PMhome), and AHI from PM+PSG (AHI PM+PSG). Two technicians, blinded to the recording order, scored each sleep study.

Results: We studied a total of 43 patients. No difference between the AHI values for each of the different recordings was found (p > 0.05). There was good correlation between AHI PSG and AHI PMhome (r = 0.67) and AHI PSG+PM (r = 0.84). The area under the receiver operator curve was above 0.83, indicating good sensitivity and a positive predictive value for AHI with cutoffs of 5, 15, and 30 and good specificity and negative predictive value for AHI values above 15. Correlation, accuracy, and agreement were greater when the recordings were made simultaneously.

Conclusions: PM was effective for diagnosing OSAS in the elderly and can be used as an alternative to PSG in elderly patients with a high clinical probability of OSAS.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11325-012-0742-yDOI Listing

Publication Analysis

Top Keywords

ahi
13
ahi psg
12
psg ahi
12
portable monitoring
8
obstructive sleep
8
sleep apnea
8
apnea syndrome
8
high clinical
8
clinical probability
8
probability osas
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!