A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and validation of a sensitive U-HPLC-MS/MS method with electrospray ionization for quantitation of ranolazine in human plasma: application to a clinical pharmacokinetic study. | LitMetric

Development and validation of a sensitive U-HPLC-MS/MS method with electrospray ionization for quantitation of ranolazine in human plasma: application to a clinical pharmacokinetic study.

J Chromatogr B Analyt Technol Biomed Life Sci

The Clinical Pharmacy & Pharmacology Research Institute, The Second Xiangya Hospital, Central South University, Changsha 410011, People's Republic of China.

Published: July 2012

A simple, sensitive and high-throughput ultra high-performance liquid chromatography electrospray ionization mass spectrometry (U-HPLC-ESI-MS/MS) method has been developed and validated for the determination of ranolazine in human plasma. Propafenone was employed as the internal standard (I.S.). The analytes were chromatographically separated on a BEH C(18) column (50 mm × 2.1 mm, 1.7 μm) with a mobile phase consisting of acetonitrile and aqueous ammonium acetate solution (0.06% formic acid, 7.5 mmol L(-1) ammonium acetate, 40:60, v/v). Detection of the analytes was achieved using positive ion electrospray ionization via multiple reactions monitoring mode. The mass transitions were m/z 428.3→279.3 for ranolazine and m/z 342.4→115.9 for propafenone. The assay was linear over the concentration range 1-3000 ng mL(-1), with correlation coefficients ≥0.997. The intra- and inter-day coefficients of variation were less than 8.9% in terms of relative standard deviation and accuracy ranged from 93.0 to 108.9% at all quality control levels. The validated method was a simple sample preparation procedure and short run-time (<2.0 min) method, which was successfully applied to a phase I pharmacokinetic study of ranolazine in Chinese healthy volunteers.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2012.06.011DOI Listing

Publication Analysis

Top Keywords

electrospray ionization
12
ranolazine human
8
human plasma
8
ammonium acetate
8
development validation
4
validation sensitive
4
sensitive u-hplc-ms/ms
4
u-hplc-ms/ms method
4
method electrospray
4
ionization quantitation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!