A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reconstruction of unstable, complex proximal humeral fractures with the da Vinci cage: surgical technique and outcome at 2 to 6 years. | LitMetric

Reconstruction of unstable, complex proximal humeral fractures with the da Vinci cage: surgical technique and outcome at 2 to 6 years.

J Shoulder Elbow Surg

Orthopaedic and Traumatology Department, Ospedale dei Pellegrini, 80134 Naples, Italy.

Published: March 2013

Background: Treatment of displaced proximal humeral fractures remains a challenge for the orthopaedic surgeon. We describe the reconstruction of such fractures with a new device designed to provide good medial cortex support and report treatment outcome.

Materials And Methods: The da Vinci device is an open triangular prism made of titanium. It is inserted in the proximal humeral cavity to stabilize the humeral head and tuberosities. Between May 2005 and December 2010, we treated 81 patients with unstable dislocated proximal fractures using this device. We report the outcome of the 69 patients monitored for at least 2 years.

Results: The results, based on the Constant-Murley and Disabilities of the Arm, Shoulder and Hand scores at a minimum of 2 years' follow-up, were excellent in 36 of 69 patients, good in 29, fair in 2, and poor in the remaining 2. Successful fracture healing was obtained in 68 of 69 patients, whereas the cage was removed in 1 patient 80 days after surgery because of infection. Partial vascular osteonecrosis occurred in 5 patients but was clinically symptomatic in only 1 of these. Fragment reduction was maintained during follow-up in all 68 cases.

Conclusions: The da Vinci cage results in good reduction and stable fixation of displaced proximal humeral fractures, as well as in cases of humeral head dislocation and comminuted fractures. Unlike other devices and screwed plates, it does not invade the subacromial space and osteosynthesis is minimally invasive.

Level Of Evidence: Level IV, Case Series, Treatment Study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2012.04.010DOI Listing

Publication Analysis

Top Keywords

proximal humeral
16
humeral fractures
12
vinci cage
8
displaced proximal
8
fractures device
8
humeral head
8
humeral
6
fractures
6
proximal
5
patients
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!