The aetiological aspects as well as postural attitude implications represent an open question in scoliosis evaluation and treatment. Leg length discrepancy (LLD) is often recognised in scoliotic patients, but surprisingly still controversial is the use of underfoot wedge corrections in order to compensate pelvis tilt. In fact, literature reports conflicting results on the efficacy of LLD equalization also given the argued uncertainty of LLD clinical assessment and limitations related to X-ray measurements. Moreover concern is about anatomic and functional LLD and associated estimation of the pelvic torsion. In such a topic, a significant helpful tool has been demonstrated to be 3D kinematic optoelectronic measurements and other useful data obtained from force platforms and/or baropodographic systems. 135 (94.4%) out of 143 Scoliotic patients sample (av. age 16.4±10.2 Y range 4-66 Y), have been found to improve posture when LLD was corrected. The 143 patients showed a mean lower limb discrepancy of μ=10.2±5.2mm associated to a mean main scoliotic curve μ=16.4°±9.4° Cobb (frontal plane), mean Spinal offset μ=7.5±5.5mm and mean Global offset μ=10.1±7.1mm. The applied paired t-test comparison (indifferent vs. corrected orthostasis) showed significant (p < 0.05) postural improvements could be obtained in the whole or in a part of the considered postural parameters, after the application of suitable under-foot wedge. The present investigation confirm results of a previous study demonstrating the efficacy of under-foot wedge use in leg asymmetry correction, posture re-balancing and spine deformities reduction, pointing out the significant contribution of the 3D opto-electronic measurement approach in the critical process of assessing the correct under-foot wedge size, therapy planning and monitoring.
Download full-text PDF |
Source |
---|
J Clin Med
December 2024
Department of Materials and Production, Aalborg University, 9220 Aalborg, Denmark.
: Spinal flexibility radiographs are important in adolescent idiopathic scoliosis (AIS) for clinical decision-making. In this study, we introduce a new method, the 'quantitatively controlled standing fulcrum side-bending' test (CSFS test). This is a feasibility study; we aimed to quantify the applied force and track the temporospatial changes in the spine specifically by measuring the continuous change in the Cobb angle (in degrees) during lateral bending.
View Article and Find Full Text PDFBioengineering (Basel)
December 2024
Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China.
This study aimed to evaluate the efficacy of a novel three-dimensional (3D) spinal decompression and correction device in improving the in-brace correction and patient comfort level for adolescents with idiopathic scoliosis (AIS), and to assess the impact of the number of vertebrae involved in the scoliotic curve on the correction's effectiveness. A single-centre, single-blinded randomized controlled trial (RCT) was conducted in 110 AIS patients aged 10-18 years who were randomly allocated into four groups receiving 0-3 days of device intervention. Each session lasted for 30 min and was conducted twice daily.
View Article and Find Full Text PDFSurg Radiol Anat
December 2024
Department of Anatomy, Digital Imaging and 3D Modelling Laboratory, Faculty of Medicine, Ege University, Bornova, 35100, Izmir, Turkey.
Purpose: The challenges of spinal surgery can be overcome by deeply understanding the anatomical and surgical complexities of the region through the use of model simulators. This study investigates the impact of digitally designed simulators, specifically lumbar spinal models with abnormal curvature, on preoperative planning and their effectiveness as training tools. The study addresses challenges in spine surgery, such as unique deformities, classification issues, and associated abdominal structure abnormalities.
View Article and Find Full Text PDFJ Med Case Rep
December 2024
"Carol Davila" University of Medicine and Pharmacology, Bucharest, Romania.
Background: Congenital scoliosis with progressive potential is a controversial subject in early-onset spinal deformities. The presence of a hemivertebra may produce severe spinal deformities. The evolution of a scoliotic curve in these cases is unpredictable and requires careful follow-up dependent on multiple variables, such as the location of the hemivertebra, the age of the patient at the time of diagnosis, and the degree of deformity already present in both sagittal and frontal planes.
View Article and Find Full Text PDFSkeletal Radiol
December 2024
Department of Radiology, Chobanian and Avedisian School of Medicine, Boston University, Boston, MA, USA.
Objective: To determine the accuracy of automatic Cobb angle measurements by deep learning (DL) on full spine radiographs.
Materials And Methods: Full spine radiographs of patients aged > 2 years were screened using the radiology reports to identify radiographs for performing Cobb angle measurements. Two senior musculoskeletal radiologists and one senior orthopedic surgeon independently annotated Cobb angles exceeding 7° indicating the angle location as either proximal thoracic (apices between T3 and T5), main thoracic (apices between T6 and T11), or thoraco-lumbar (apices between T12 and L4).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!