A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The effects of ultrasonic and electrosurgery devices on nerve physiology. | LitMetric

Background: While the risks associated with the use of electrosurgery near nerves are well known, few studies have examined the neurophysiologic effects of application of the Harmonic Blade, an ultrasonic scalpel, in the vicinity of nerve fibres. This study sought to compare the sub-acute neurophysiologic effects of the Harmonic Blade and electrosurgery after incisions close to the sciatic nerve.

Methods: Incisions were made in rats with the Harmonic Blade and electrosurgery at distances of 1, 2, 3 and 4 mm from the sciatic nerve. Sham surgery was also performed. The compound action potential, conduction velocity and calibrated nylon filament (von Frey hair, VFH) stimulating force were monitored for up to 3 hours after surgery. The sciatic nerve was assessed for inflammation via H&E staining and impaired axonal transport by β-APP immunohistochemistry.

Results: Electrosurgery incisions produced a significantly greater decrease in compound action potential and conduction velocity, and increase in the VFH force than the Harmonic Blade over all time points and distances from the sciatic nerve. The Harmonic Blade was similar to sham surgery for the compound action potential and VFH force. Electrosurgery yielded significantly greater leukocyte infiltration than the Harmonic Blade and produced the highest levels of β-APP immunoreactive swellings.

Conclusions: Incisions with electrosurgery in the range of 1-4 mm of the sciatic nerve caused substantial changes in neurophysiologic functioning and inflammation. In contrast, the Harmonic Blade was similar to sham surgery in the vicinity of the nerve, producing little observable acute trauma.

Download full-text PDF

Source
http://dx.doi.org/10.3109/02688697.2012.697216DOI Listing

Publication Analysis

Top Keywords

harmonic blade
28
sciatic nerve
16
sham surgery
12
compound action
12
action potential
12
neurophysiologic effects
8
vicinity nerve
8
blade electrosurgery
8
electrosurgery incisions
8
distances sciatic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!