Exhaled breath condensate (EBC) collection is an innovative method of non-invasively sampling the lung, and can detect a variety of volatile and non-volatile biomarkers, but the disadvantage is the small volume of sample collected. It was hypothesized that a collection system at a lower temperature would increase the volume collected, but may alter the relative concentration of the biomarkers of interest. EBC was collected in a cross-over study using a custom-made collection system, cooled using either wet (4 °C) or dry ice (-20 °C) in randomized order in normal non-smoking volunteers. The volume of the EBC collected per unit time was determined as were conductivity, the concentrations and total amount of protein, hydrogen peroxide, and nitrite/nitrate concentrations. Dry ice was associated with a 79% greater volume of EBC than the wet ice (1387 ± 612 µL; 773 ± 448 µL respectively, p < 0.0001). Conductivity was influenced by the temperature of collection (18.78 ± 6.71 µS cm(-1) for wet ice and 15.32 ± 6.28 µS cm(-1) for dry ice, p = 0.02) as was hydrogen peroxide (1.34 ± 0.88 µg mL(-1) for wet ice and 0.68 ± 0.32 µg mL(-1) for dry ice, p = 0.009) while the concentrations and total values for protein and nitrate/nitrite were not significantly different (p > 0.05). This pilot study suggests that lower collection temperatures facilitate the collection of a larger sample volume. This larger volume is not simply more dilute, with increased water content, nor is there a simple correction factor that can be applied to the EBC biomarkers to correct for the different methods.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1752-7155/6/3/036002 | DOI Listing |
Plant Methods
December 2024
Crop, Livestock and Environment Division, Japan International Research Center for Agricultural Sciences, Ohwashi 1-1, Tsukuba, Ibaraki, Japan.
Background: Gene expression is a fundamental process for plants to express their phenotype, and its analysis is the basis of molecular studies. However, the instability of RNA often poses an obstacle to analyzing plants grown in fields or remote locations where the availability of liquid nitrogen or dry ice is limited. To deepen our understanding of plant phenotypes and tolerance to field-specific stresses, it is crucial to develop methodologies to maintain plant RNA intact and safely transfer it for downstream analyses such as qPCR and RNA-seq.
View Article and Find Full Text PDFSci Rep
December 2024
Physical Geography, Institute of Geography, Technical University Dresden, Dresden, Germany.
It is generally accepted that a weakening of the North Atlantic thermohaline circulation caused the Younger Dryas cooling. Although the role of seasonality was emphasized previously, this aspect is rarely considered yet, and it remains elusive how this impacted hydroclimate during winters and summers across Central Europe. Here, we coupled biomarker-based δO and δH from Bergsee in southern Germany to reconstruct deuterium excess as a proxy for evaporation history from the Bølling-Allerød to the Preboreal.
View Article and Find Full Text PDFInfluenza Other Respir Viruses
December 2024
Laboratory for Drug Discovery and Disease Research, Shionogi & Co, Ltd, Osaka, Japan.
Background: Evaluation of infectious virus titer is a challenge for respiratory syncytial virus (RSV) clinical trials because of the labile nature of RSV and rapid loss of infectivity without proper specimen handling. However, there has been no rigorous investigation into RSV stability in clinical specimens.
Methods: RSV stability was investigated by evaluating virus titers and defined as titer variation from baseline within three standard deviations of our titration assay.
Rapid Commun Mass Spectrom
February 2025
School of Earth, Environment & Society, McMaster University, Hamilton, ON, Canada.
Rationale: The stable isotope compositions of atmospheric CO can provide useful insight into various geochemical processes and carbon cycles on Earth, which is critical for understanding of Earth's changing climate. Here, we present a simple and cost-effective analytical method for the collection and measurement of carbon and oxygen isotope compositions of atmospheric CO.
Methods: Air samples of ~150 mL were collected individually or collectively using our simple active air collection system and then extracted on a vacuum purification line to remove noncondensable gases and atmospheric water vapor.
Glob Chang Biol
December 2024
Museo Nacional de Ciencias Naturales, Consejo Superior de Investigaciones Científicas, Madrid, Spain.
Global change is causing the melting of ice masses, permafrost thawing, and the shrinking of glaciers, thereby reshaping nature's rhythms. Longer thaw phases and more frequent dry periods are transforming water-driven transitional ecosystems (e.g.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!