Patients who present with significant paravalvular regurgitation after mitral valve replacement remain a difficult patient population and high-risk surgical candidates. We present 3 cases of transapical closure of mitral valve paravalvular leak (PVL) after mitral valve replacement using Amplatzer closure devices (AGA Medical Corp, Plymouth, MN). All 3 patients experienced decreased regurgitation at the site of the closure as well as symptomatic improvement in their heart failure.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.athoracsur.2011.12.035DOI Listing