A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fetal movement counting at home with a fetal movement acceleration measurement recorder: a preliminary report. | LitMetric

Fetal movement counting at home with a fetal movement acceleration measurement recorder: a preliminary report.

J Matern Fetal Neonatal Med

Department of Obstetrics and Gynecology, Teikyo University, School of Medicine, Kaga, Itabashi-ku, Tokyo, Japan.

Published: December 2012

Objective: Fetal Movement Acceleration Measurement (FMAM) recorder was developed to facilitate gross fetal movement counting. The aim was to assess its reliability.

Methods: Using the recorder, six pregnant women recorded fetal movements by themselves when they slept at their home weekly from 30 weeks to term. The recorder has 2 acceleration sensors; 1 for fetal movement (FM sensor) and another for maternal movement (MM sensor). Before sleeping, each subject attached the FM sensor to her abdomen, and the MM sensor to her thigh. All the recorded data were divided into 10-sec epochs, and presence of fetal movements was judged for all epochs (total epoch). The epoch was judged as positive for movement (positive epoch) when the FM sensor detected abdominal wall oscillations and the MM sensor did not detect maternal movements. The percentage of positive epoch number to total epoch and the maximum consecutive negative epoch number was calculated.

Results: The mean percentage was approximately 20-25% at 30-34 weeks and 10-15% at 35-38 weeks. The negative epoch number linearly increased after approximately 33-34 weeks of gestation.

Conclusions: The FMAM recorder was reliable for long-duration recording of gross fetal movements at home.

Download full-text PDF

Source
http://dx.doi.org/10.3109/14767058.2012.704449DOI Listing

Publication Analysis

Top Keywords

fetal movement
20
fetal movements
12
epoch number
12
fetal
8
movement counting
8
movement acceleration
8
acceleration measurement
8
fmam recorder
8
gross fetal
8
movement sensor
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!