In low-level sensory systems, it is still unclear how the noisy information collected locally by neurons may give rise to a coherent global percept. This is well demonstrated for the detection of motion in the aperture problem: as luminance of an elongated line is symmetrical along its axis, tangential velocity is ambiguous when measured locally. Here, we develop the hypothesis that motion-based predictive coding is sufficient to infer global motion. Our implementation is based on a context-dependent diffusion of a probabilistic representation of motion. We observe in simulations a progressive solution to the aperture problem similar to physiology and behavior. We demonstrate that this solution is the result of two underlying mechanisms. First, we demonstrate the formation of a tracking behavior favoring temporally coherent features independent of their texture. Second, we observe that incoherent features are explained away, while coherent information diffuses progressively to the global scale. Most previous models included ad hoc mechanisms such as end-stopped cells or a selection layer to track specific luminance-based features as necessary conditions to solve the aperture problem. Here, we have proved that motion-based predictive coding, as it is implemented in this functional model, is sufficient to solve the aperture problem. This solution may give insights into the role of prediction underlying a large class of sensory computations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3472550PMC
http://dx.doi.org/10.1162/NECO_a_00332DOI Listing

Publication Analysis

Top Keywords

aperture problem
20
solve aperture
12
sufficient solve
8
motion-based predictive
8
predictive coding
8
aperture
5
problem
5
motion-based prediction
4
prediction sufficient
4
problem low-level
4

Similar Publications

Inverse design with topology optimization considers a promising methodology for discovering new optimized photonic structure that enables to break the limitations of the forward or the traditional design especially for the meta-structure. This work presents a high efficiency mid infra-red imaging photonics element along mid infra-red wavelengths band starts from 2 to 5 µm based on silicon nitride optimized material structures. The first two designs are broadband focusing and reflective meta-lens under very high numerical aperture condition (NA = 0.

View Article and Find Full Text PDF

Set-up errors are a problem for pre-clinical irradiators that lack imaging capabilities. The aim of this study was to investigate the impact of the potential set-up errors on the dose distribution for a mouse with a xenographic tumour irradiated with a standard Cs-137 cell irradiator equipped with an in-house lead collimator with 10 mm diameter apertures. The EGSnrc Monte-Carlo (MC) code was used to simulate the potential errors caused by displacements of the mouse in the irradiation setup.

View Article and Find Full Text PDF

Objective: The most common medically resistant epilepsy (MRE) involves the temporal lobe (TLE), and children designated as temporal plus epilepsy (TLE+) have a five-times increased risk of postoperative surgical failure. This retrospective, blinded, cross-sectional study aimed to correlate visual and computational analyses of magnetoencephalography (MEG) virtual sensor waveforms with surgical outcome and epilepsy classification (TLE and TLE+).

Methods: Patients with MRE who underwent MEG and iEEG monitoring and had at least 1 year of postsurgical follow-up were included in this retrospective analysis.

View Article and Find Full Text PDF

Hybrid nanoplasmonic structures composed of subwavelength apertures in metallic films and nanoparticles have recently been demonstrated as ultrasensitive plasmonic sensors. This work investigates the electrokinetically driven propagation of the assembly mechanism of the metallic nanoparticles through nanoapertures. The Debye-Hückel approximation for a symmetric electrolyte solution with overlapping electrical double layers (EDLs) is used to obtain an analytical solution to the problem.

View Article and Find Full Text PDF

Aiming at the problem of overbrightness of the target simulator background for LED backlight panel illumination, a 5° aperture angle-matched collimated illumination method for the target simulator is proposed based on the study of the dark-state leakage of the LCD display device and the scattered stray light of the system. After simulation analysis the method can make the display contrast increase by 3.1 times and solve the problem of dark targets being drowned by the background bright light, which exists in the LED illumination target simulator.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!