Between 2005 and 2010 ten consecutive children with high-energy open diaphyseal tibial fractures were treated by early reduction and application of a programmable circular external fixator. They were all male with a mean age of 11.5 years (5.2 to 15.4), and they were followed for a mean of 34.5 months (6 to 77). Full weight-bearing was allowed immediately post-operatively. The mean time from application to removal of the frame was 16 weeks (12 to 21). The mean deformity following removal of the frame was 0.15° (0° to 1.5°) of coronal angulation, 0.2° (0° to 2°) sagittal angulation, 1.1 mm (0 to 10) coronal translation, and 0.5 mm (0 to 2) sagittal translation. All patients achieved consolidated bony union and satisfactory wound healing. There were no cases of delayed or nonunion, compartment syndrome or neurovascular injury. Four patients had a mild superficial pin site infection; all settled with a single course of oral antibiotics. No patient had a deep infection or re-fracture following removal of the frame. The time to union was comparable with, or better than, other published methods of stabilisation for these injuries. The stable fixator configuration not only facilitates management of the accompanying soft-tissue injury but enables anatomical post-injury alignment, which is important in view of the limited remodelling potential of the tibia in children aged > ten years. Where appropriate expertise exists, we recommend this technique for the management of high-energy open tibial fractures in children.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1302/0301-620X.94B7.28333 | DOI Listing |
JBJS Case Connect
January 2025
Department of Orthopedic Surgery, Albany Medical Center, Albany, New York.
Case: We present the case of a 24-year-old woman who sustained a left midshaft clavicle fracture with acute subclavian artery compression, subclavian vein laceration, and complete brachial plexus palsy after a motor vehicle collision. The patient underwent urgent open reduction internal fixation of the clavicle and repair of the subclavian vein. Two years later, she underwent opponensplasty and flexor digitorum profundus tendon transfers.
View Article and Find Full Text PDFPhys Rev Lett
December 2024
Stanford University, Department of Mechanical Engineering, Stanford, California 94305, USA.
The extreme electric fields created in high-intensity laser-plasma interactions could generate energetic ions far more compactly than traditional accelerators. Despite this promise, laser-plasma accelerator experiments have been limited to maximum ion energies of ∼100 MeV/nucleon. The central challenge is the low charge-to-mass ratio of ions, which has precluded one of the most successful approaches used for electrons: laser wakefield acceleration.
View Article and Find Full Text PDFiScience
January 2025
Institute of Polymer Optoelectronic Materials and Devices, State Key Laboratory of Luminescent Materials and Devices, South China University of Technology, Guangzhou 510640, China.
Organic solar cells (OSCs) have developed rapidly in recent years. However, the energy loss ( ) remains a major obstacle to further improving the photovoltaic performance. To address this issue, a ternary strategy has been employed to precisely tune the and boost the efficiency of OSCs.
View Article and Find Full Text PDFCureus
December 2024
Medical Research, Universidad Francisco Marroquín, Guatemala, GTM.
Scapular fractures are rare, typically resulting from high-energy trauma. These injuries frequently present alongside other thoracic or shoulder injuries. Patients often exhibit posterior shoulder pain, swelling, and limited range of motion, which can suggest a variety of shoulder pathologies.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopedic Surgery, Anam Hospital, Korea University College of Medicine, 73 Goryeodae-ro Seongbuk-gu, Seoul 02841, Republic of Korea.
Distal tibia fractures are high-energy injuries characterized by a mismatch between standard plate designs and the patient's specific anatomical bone structure, which can lead to severe soft tissue damage. Recent advancements have focused on the development of customized metal plates using three-dimensional (3D) printing technology. However, 3D-printed metal plates using titanium alloys have not incorporated a locking system due to the brittleness of these alloys.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!