Background: Intraneural injection of local anaesthetic agents carries a risk of neurological complications. Early detection of intraneural needle-tip position is very important in the initial phase of injection. Ultrasound (US) characteristics for real-time detection of intraneural injections have been described, but only for relatively large volumes (5-40 ml). This study assesses the reliability of various US criteria to detect early low volume (0.5 ml) intraneural injections. Intraneural deposition of an injected dye was confirmed by cryomicrotomy.

Methods: In nine unembalmed human cadavers, 0.5 ml methylene blue was injected intraneurally into the supraclavicular brachial plexus and subgluteal sciatic nerve on both sides. The sites of injection were subsequently removed en bloc. Consecutive cryomicrotomy cross-sections with a 50 µm interval were obtained to assess intraneural presence of the injectate. Two independent experts separately reviewed US video clips of the injections and scored each US criterion.

Results: Of the 36 injections, cryomicrotome cross-sections showed intraneural staining in 33 and extraneural staining in three. The best US criterion was expansion of the nerve cross-sectional surface area together with a change in echogenicity. It was observed in 35 injections, including two false positives. There was one true negative. Test precision was 94% [95% confidence interval (CI), 87-100%]. The mean increase in surface area was 8.7% (95% CI, 5.6-11.9).

Conclusions: Reliable detection of early low-volume intraneural injection using US is possible using expansion of the cross-sectional surface area of the nerve together with a change in echogenicity as markers.

Download full-text PDF

Source
http://dx.doi.org/10.1093/bja/aes208DOI Listing

Publication Analysis

Top Keywords

intraneural injection
12
surface area
12
intraneural
9
low-volume intraneural
8
detection intraneural
8
intraneural injections
8
cross-sectional surface
8
change echogenicity
8
injection
5
injections
5

Similar Publications

Risk of intrafascicular spread after deliberate ex vivo intraneural injections of brachial plexus nerve roots.

Br J Anaesth

January 2025

Department of Anesthesiology, University of Florida College of Medicine, Gainesville, FL, USA; CEU-San-Pablo University School of Medicine, Madrid, Spain; Department of Anesthesiology, Madrid-Montepríncipe University Hospital, Madrid, Spain. Electronic address:

Background: We investigated the intraneural spread of injected fluid in brachial plexus nerve roots, examining the potential for intrafascicular spread and identifying influencing factors.

Methods: Twelve deliberate ultrasound-guided intraneural injections were performed at the ventral rami of the brachial plexus nerve roots at their exits from the neuroforamina in six fresh, unembalmed, cryopreserved human cadavers. A 22-G, 30-degree bevel echogenic regional anaesthesia needle was used.

View Article and Find Full Text PDF
Article Synopsis
  • Inadvertent intraneural injections during peripheral nerve blocks are common, and this study compares two detection methods: injection pressure monitoring and ultrasound imaging.
  • The research involved anesthesiologists conducting intraneural injections on fresh cadaver arms, measuring both pressure and sonographic images to evaluate outcomes.
  • Results showed that pressure monitoring detected intraneural injection much earlier than ultrasound (after just 0.2 mL vs. 1.2 mL for swelling), confirming that pressure monitoring is a more sensitive technique.
View Article and Find Full Text PDF

Intraneural Device for Electrostimulation of Vagus Nerve in Rats: A Feasibility Study for Modulating Glucose Tolerance.

Neuromodulation

November 2024

Laboratory of Energy and Data Science, Division of Smart Sector Integration, Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Casaccia Research Center, Rome, Italy. Electronic address:

Objectives: This study introduces EMPATIC (Electro-Modulation of PAncreaTic Islet Cells), a miniaturized intraneural device designed for transversal insertion into small nerves with a mean diameter of 400 μm. EMPATIC aims to modulate glucose tolerance through intraneural vagus nerve stimulation (VNS) in rats.

Materials And Methods: EMPATIC design was optimized to fit into the cervical vagus nerve of rats and was developd through thin film microtechnologies.

View Article and Find Full Text PDF

New prospects for Zr-immuno-PET in brain applications - Alpha-synucleinopathies.

Nucl Med Biol

November 2024

Amsterdam UMC location Vrije Universiteit Amsterdam, Dept Radiology & Nuclear Medicine, De Boelelaan 1117, Amsterdam, the Netherlands; Amsterdam Neuroscience, Brain Imaging, Amsterdam, the Netherlands. Electronic address:

Article Synopsis
  • * Background research highlights how Zr-immuno-PET imaging can effectively visualize therapeutic antibodies utilizing transferrin-mediated transport across the blood-brain barrier and emphasizes the significance of alpha-synuclein in diseases like Parkinson’s.
  • * The methodology involved conjugating antibodies with a chelator and using various analyses, including radioim
View Article and Find Full Text PDF

Intraneural ganglion cysts (IGCs) are mucinous cysts located within peripheral nerves, often associated with an articular nerve branch and the adjacent synovial joint capsule. These cysts, while rare, can occur in various nerves, with the tibial nerve being an infrequent site. Tibial nerve IGCs are rare pathologies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!