Background: We reviewed our experience with the surgical management of supravalvar aortic stenosis (SVAS) to determine long-term outcomes and factors related to late reoperation.

Methods: Between August 1956 and May 2009, 78 patients (50 males) underwent surgical correction of SVAS. Median age was 10.4 years (range, 16 days to 55.2 years). Mean preoperative gradient was 57.2±21.9 mm Hg with a mean peak gradient of 99.5±34.8 mm Hg. Supravalvar aortic stenosis was discrete in 51 patients (64%) and diffuse in 27 patients (35%). Aortic valve stenosis was present in 22 patients (29%). Williams-Beuren syndrome was present in 32 patients (41%).

Results: Surgery was either a diamond-shaped patch in 67 patients (85.9%) or a pantaloons-shaped patch in 11 patients (14.1%). Aortic valve intervention was required in 20 patients (25.64%). Mean gradient immediately after repair was 25±25 mm Hg, with 13 patients (16.7%) having a residual gradient. A high residual gradient was more likely in the diffuse group (odds ratio, 3.73; 95% confidence interval, 1.07 to 12.98). There were 2 (2.6%) early deaths, both with diffuse SVAS. Median follow-up was 19.8 years; maximum was 48.5 years. The mean gradient across the left ventricular outflow tract at late follow-up was 8.8 mm Hg (95% confidence interval, 3.7 to 14.01). Overall survival was estimated at 90%±7%, 84%±9%, and 8%2±10% at 5, 10, and 20 years, respectively. Predictors of mortality were age younger than 2 years (p=0.021), diffuse SVAS (p=0.045), aortic valve stenosis (p=0.032), and high postoperative gradient (p=0.023). Presence of Williams-Beuren syndrome did not affect survival (p=0.305). Freedom from late reoperation was 97%±4%, 93%±7%, and 86%±10% at 5, 10, and 20 years, respectively. Significant aortic valve disease (p<0.001) and diffuse SVAS (p=0.009) were risk factors for late reoperation.

Conclusions: Surgical repair for SVAS can be performed with a single-patch technique with good long-term outcome. Late mortality and need for reoperation are more likely with diffuse SVAS or the presence of aortic valve stenosis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.athoracsur.2012.04.022DOI Listing

Publication Analysis

Top Keywords

aortic valve
16
supravalvar aortic
12
aortic stenosis
12
patients
9
svas median
8
valve stenosis
8
williams-beuren syndrome
8
patch patients
8
residual gradient
8
95% confidence
8

Similar Publications

Acute aortic dissection during minimally invasive cardiac surgery: a case report.

JA Clin Rep

January 2025

Department of Anesthesiology, Saiseikai Kumamoto Hospital, 5-3-1 Minami-Ku, Chikami Kumamoto, 861-4193, Japan.

Background: Management of acute aortic dissection (AAD) caused by retrograde perfusion through the femoral artery during minimally invasive cardiac surgery (MICS) remains controversial. We present a case of AAD occurring during the late cardiopulmonary bypass (CPB) phase, which was successfully managed by vascular graft replacement, without altering the blood supply route.

Case Presentation: A 63-year-old man was scheduled for totally endoscopic aortic valve replacement.

View Article and Find Full Text PDF

A 77-year-old man with a history of a Bentall procedure presented with acute decompensated heart failure. Investigations revealed severe bioprosthetic aortic valve regurgitation and a large pseudoaneurysm eroding the sternum. We describe the multimodal imaging and heart team planning to stent the pseudoaneurysm with an endograft followed by transcatheter valve-in-valve implantation.

View Article and Find Full Text PDF

We describe the case of a 52-year-old man with radiation-induced severe mixed aortic and mitral valve disease, thickening of the aortomitral continuity, mitral annular calcification, and porcelain aorta with limited transcatheter treatment options. By replacing the aorta during circulatory arrest, we demonstrate that it is possible to clamp the ascending aorta to facilitate prosthetic aortic and mitral valve replacement.

View Article and Find Full Text PDF

Decoding High Post-TAVR Gradients: Insights From 4 Clinical Scenarios.

JACC Case Rep

January 2025

Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua Medical School, Padua, Italy.

Echocardiography is a well-established tool for evaluating bioprosthetic valve performance after transcatheter aortic valve replacement. The presence of higher-than-expected echocardiographic gradients is not an uncommon finding and can be related to different clinical settings. This case series proposes a practical and multiparametric approach to interpreting high residual gradients after transcatheter aortic valve replacement.

View Article and Find Full Text PDF

Background: Degenerative severe aortic stenosis (AS) is treated by valve replacement to improve outcome. Despite diagnostic advancements, many AS patients are still diagnosed late with advanced heart failure.

Objectives: The aim of the study was to assess multiorgan dysfunction in severe AS using blood biomarkers and their association with quantitative fluid levels and clinical outcomes after transcatheter aortic valve implantation (TAVI).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!