Objectives: This study sought to assess the impact of permanent pacemaker (PPM) implantation on clinical outcomes among patients undergoing transfemoral transcatheter aortic valve implantation (TAVI).

Background: TAVI is associated with atrioventricular-conduction abnormalities requiring PPM implantation in up to 40% among patients treated with self-expanding prostheses.

Methods: Between 2007 and 2010, 353 consecutive patients (mean age: 82.6 ± 6.1 years, log EuroSCORE: 25.0 ± 15.0%) with severe aortic stenosis underwent transfemoral TAVI at 2 institutions. Clinical outcomes were compared among 3 groups: (1) patients requiring PPM implantation after TAVI (PPM after TAVI), (2) patients without PPM before or after TAVI (no PPM), and (3) patients with PPM before TAVI (PPM before TAVI). The primary endpoint was all-cause mortality at 12 months, and an age-, sex-, and origin-matched standardized population served as controls.

Results: Of 353 patients, 98 patients (27.8%) belonged to the PPM after TAVI group, 48 patients (13.6%) belonged to the PPM before TAVI group, and 207 patients (58.6%) belonged to the no PPM group. The PPM before TAVI patients had a significantly higher baseline risk compared with the PPM after TAVI and no PPM patients (coronary artery disease: 77.1% vs. 52.7% and 58.2%, respectively, p = 0.009; atrial fibrillation: 43.8% vs. 22.7% and 20.4%, respectively, p = 0.005). At 12 months of follow-up, all-cause mortality was similar in all 3 groups (PPM after TAVI group: 19.4%, PPM before TAVI group: 22.9%, no PPM group: 18.0%) in unadjusted analyses (p = 0.77) and adjusted analyses (p = 0.90). Compared with the standardized population, adjusted hazard ratios for death were 2.37 (95% confidence interval [CI]: 1.51 to 3.72) for the PPM after TAVI group, 2.75 (95% CI: 1.52 to 4.97) for the PPM before TAVI group, and 2.24 (95% CI: 1.62 to 3.09) for the no PPM group.

Conclusions: Although prognosis remains impaired compared with an age-, sex-, and origin-matched standardized population, periprocedural PPM implantation does not seem to affect clinical outcomes adversely among patients undergoing transfemoral TAVI.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacc.2012.03.054DOI Listing

Publication Analysis

Top Keywords

ppm tavi
48
tavi group
24
ppm
21
ppm implantation
16
tavi
16
tavi ppm
16
patients
14
patients undergoing
12
clinical outcomes
12
standardized population
12

Similar Publications

Introduction: Conductive disturbances requiring permanent pacemaker (PPM) implantation remain a major concern after transcatheter aortic valve implantation (TAVI).

Aims: To assess the impact of aortic valve calcium score (AVCS) on conductive disturbances requiring PPM after TAVI.

Methods: All patients who underwent TAVI with accessible AVCS from the preprocedural CT scan report were included in this retrospective single-centre study.

View Article and Find Full Text PDF

Background: Evidence regarding the incidence of prosthesis-patient mismatch (PPM) and long-term mortality after transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS) is scarce.

Objectives: This study sought to assess the incidence and prognostic impact of PPM after TAVR for bicuspid AS compared with that for tricuspid AS.

Methods: In total, 7,393 patients who underwent TAVR were prospectively enrolled in the OCEAN-TAVI (Optimized Catheter Valvular Intervention Transcatheter Aortic Valve Implantation) registry, an ongoing Japanese, multicenter registry.

View Article and Find Full Text PDF

Background: The management of Transcatheter Aortic Valve Implantation (TAVI) patients with a small aortic annulus (SAA) postures a substantial challenge, increasing the risk of patient- prosthesis mismatch (PPM) and overall mortality.

Aims: This study aimed to compare the hemodynamic and clinical outcomes of transcatheter balloon-expandable valve (BEV) versus transcatheter self-expandable valve (SEV) in SAA.

Methods: We conducted propensity score matching (PSM) of severe AS patients with SAA who underwent trans-femoral TAVR and enrolled to the Israeli TAVR registry between the years 2008 and 2023.

View Article and Find Full Text PDF

Background: Prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) is of greater concern in Asians, considering their relatively smaller annular sizes compared with Westerners. However, the prognostic significance of PPM in Asian populations has not been demonstrated.

Objectives: This study aimed to elucidate the prognostic value of PPM after TAVR in Asian patients.

View Article and Find Full Text PDF

Long-Term Mortality and Impact of Implantation-Associated Factors on the Incidence of Patient-Prosthesis Mismatch After Transcatheter Aortic Valve Implantation in Patients With Small Annuli.

Am J Cardiol

February 2025

Department of Cardiology, University Heart and Vascular Center Hamburg, Germany; German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Lübeck/Kiel, Germany; Department of Cardiology and Angiology, BG University Hospital Bergmannsheil, Ruhr University Bochum, Germany.

Prosthesis-patient mismatch (PPM) is a common phenomenon after transcatheter aortic valve implantation (TAVI), especially in patients with small aortic annuli. Whether factors during implantation, such as the implantation depth, have an impact on the occurrence of PPM is currently unclear. The objectives of our study were to (1) investigate the influence of procedure planning- and implantation-related factors on the occurrence of PPM and (2) evaluate the impact of PPM on long-term mortality after TAVI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!